Page 3
Minimum Clearances to Combustibles The clearances listed below are minimum distances unless otherwise stated. A major cause of fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this decorative gas appliance is installed only in accordance with these instructions. J*** Diagram 1 Clearance...
Page 4
Mantel Clearances Without Mantel Deflector Mantel Clearances with 2-1/2" Mantel Deflector 24" 24" 22" 22" 20" 20" 18" 18" 16" 16" 14" 14" 12" 12" 10" 10" 8" 8" 6" 6" Mantel Deflector 4" 4" 2" 2" 0" 0" Top of Top of fireplace fireplace...
Page 6
Using Steel Studs and Concrete Board Over Masonry Brick Fireplace The masonry front brick facing can be removed and replaced with non-combustible materials such as steel studs and concrete board/dura rock/micor board as per diagram 1, only if safe to do so. Steel stud may also be placed in front of the masonry brick if left in place. This is the preferred method depending on the condition of the masonry brick fireplace.
Page 7
Gas Connection Only people licensed to work with gas piping may make the gas connections to this appliance. 1. If the appliance is installed into an existing chimney system, thoroughly clean the masonry or factory-built fireplace. 2. The appliance has an opening on the right side of the control compartment.
Page 8
Alternate Approved Vertical Termination Caps/Adaptor Alternate Approved Caps Option 1 46DVA-CL33 - Vertical High Wind Cap With Flashing. Also includes 3" (76 mm) x 35' (10.7 m) Air Inlet Liner & 3" (76 mm) x 35' (10.7 m) Exhaust Liner Option 2 46DVA-VC Vertical Termination Cap - Low profile 46DVA-VCH Vertical High Wind Cap...
Page 9
Vertical Venting/Restrictor Settings for NG and LP Setting #3 Setting #4 4-1/2" open 2" open Setting #2 2-1/2" open Setting #1 Setting #2 1" open 2-1/2" open Gi29LE Gas Insert |...
Page 10
Vertical Venting/Restrictor Settings for FPI Co-Linear DV Vertical Termination Cap & Flashing (946-529) Enclosed IMPORTANT: Vent cap clearances to Sides and Top must be followed. See next page for important clearance requirements when termination cap is enclosed above and on 2 sides. Not approved for use with either the 46DVA-CL33 or 46DVA-GK + 46DVA-VCH Termination Caps/Adaptor Original Masonry Chimney Rain Cap...
Page 11
Vertical Venting/Clearance Requirements for FPI Co-Linear DV Vertical Termination Cap & Flashing (946-529) Enclosed When installed with 46DVA-CL33 or 46DVA-GK + 46DVA-VCH + 3" FPI Flex (Exhaust/Air Intake), the clearances below do not apply, all noted caps must be free and clear of obstructions on all sides. Situation 1 Situation 2 Situation 3...
Page 12
Horizontal Co-Linear Vent Kit (Masonry Fireplaces Only) APPLICATION This instruction applies to the DuraVent Direct Vent Pro termination system and is intended as a supplement to the applicable Direct Vent Pro instructions. This termination and venting system and the gas appliance were tested and listed by an accredited test agency. Kit # 46DVA-HCL33 includes: 1 Horizontal Termination Cap Two 10' (3 m) long x 3"...