Fig 1 - Parts identification
FTC5 Controller
Automatic Air Vent
Low loss header
3 Way motorised
diverter valve
Primary circuit
pressure gauge
Primary circulation
pumps
Immersion heater
housing
Flow sensor
Primary circuit
drain o point
Solar coil connections
(Solar models only)

Indicative Performance

Nominal capacity
(litres)
150
170
150
300
300
NOTE: Heating times achieved using an Air Source Heat Pump with variable output power and boost heating to 60
a 3kW immersion heater and a primary (heat pump) flow rate of 20 l/min. Test method in accordance with EN12897:2006
6

Hot Water Outlet

Type
Hot water capacity
(litres)
Slimline
144
Slimline
175
Standard
153
Standard
301
Solar
302
Magnetic lter
Expansion Valve
Temperature/Pressure
Relief Valve
Tundish
DHW circulating
pump
Expansion vessel
tapping
Scale Trap
Plate to Plate heat
exchanger
DHW Drain o
point
Solar controls housing
(Solar models only)
Reheat time
Nominal heat input
(minutes)
92
69
65
172
135
(kW)
4.83
7.85
7.20
5.38
6.88
Average 6.43