Valeo THERMO PLUS 300 Operating And Service Instructions

Valeo THERMO PLUS 300 Operating And Service Instructions

Hide thumbs Also See for THERMO PLUS 300:

Advertisement

HEATING SYSTEMS
THERMO PLUS
230/300/350
Operating and
service instructions
NOTE: Subject to modification. In multilingual
versions the German language is binding. The
latest version of this document is provided for
download on www.valeo-thermalbus.com.
Rev. 05/2018
Id.No. 11121148B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the THERMO PLUS 300 and is the answer not in the manual?

Questions and answers

Summary of Contents for Valeo THERMO PLUS 300

  • Page 1 HEATING SYSTEMS THERMO PLUS 230/300/350 Operating and service instructions NOTE: Subject to modification. In multilingual versions the German language is binding. The latest version of this document is provided for download on www.valeo-thermalbus.com. Rev. 05/2018 Id.No. 11121148B...
  • Page 2: General Information

    1500 m above MSL and up to 2000 m above MSL if that is a short stay in such conditions (pass crossing, break). In case of a permanent heater operation above 1500m the CO setting must be readjusted by Valeo trained personnel, due to a change of the exhaust gas values depending on environmental conditions. Service and safety instructions For the heater exist type approvals according to ECE Regulations R122 (Heater) and R10 (EMC).
  • Page 3 An up-to-date list of anti-freeze approved by Valeo can be found on the Valeo website. The heater must: with a diesel fuel approved by Valeo in accordance with DIN EN 590 (see TI's Fuels on the Valeo website for more information) and the rated voltage shown on the model plate.
  • Page 4: Heater Operation

    Operating and service instructions Heater operation The water heater can be switched on using either a switch or digital timer. Before you switch on the heater set the vehicle's heating system to “Warm”. Pre-selection timer 1 Menu button 9 10 2 Selection button UP 3 Instant heating button 4 Confirmation button...
  • Page 5 Thermo Plus 230/300/350 the week, the hours and the minutes. Switch the preselection timer off Confirm each respectively using - switch off ignition (the preselection timer Note: In the 12h mode, after setting of the goes into the sleep mode) minutes, further choose AM or PM by the - the timer turns off after the expiry of selection buttons - confirm using...
  • Page 6 Additional to the fault lock-out a heater lock-out occurs if safety related components are affected. The fault code 12 will be displayed (see para. “Flash code“). If a heater lock-out has occurred, the heater must be maintained and released by Valeo trained personnel.
  • Page 7: Flash Code

    Thermo Plus 230/300/350 Flash code The kind of malfunction is indicated from the operating indication light through a flash code or if the pre-selection timer is used in the display (operation display). The flash code is immediately generated after detection of the malfunction and will be kept until the heater is freed.
  • Page 8 Valeo Thermal Commercial Vehicles Germany GmbH Friedrichshafener Str. 7 - 82205 Gilching - Germany Tel. +49 (0)8105 7721-0 Fax +49 (0)8105 7721-889 www.valeo-thermalbus.com - service-valeobus@valeo.com...