INSTALLING THE BOILING CHAMBER

Your distiller has been shipped with the boiling chamber already in place. If it
has been disturbed during shipping follow the simple steps listed below to
reinstall the boiling chamber.
CAUTION:
To avoid personal injury or property damage, be certain
distiller is unplugged.
1) Place the hook of the boiling chamber over the lift spring bracket located
in the front half of the distiller.
2) Be sure the gasket is securely in place over the top rim of the boiling chamber.
3) Fit the lid with the attached tubes over the gasket and onto the boiling
chamber making sure that the threaded center support protrudes
through the hole in the lid. Ensure that the tubes are centered in the
distiller openings.
4) Secure the lid by turning the cover knob clockwise.
5) Make sure that the boiling chamber moves freely up and down by
pressing down on the top of the boiling chamber. The boiling chamber
should lift when it is released. If the boiling chamber does not move
freely, recheck all connections.
6) Fully insert the boiling chamber power cord into the receptacle. A loose
connection may damage the power cord and result in failure of
the distiller. Be sure the plug is fully inserted into the socket.
Lift Spring Bracket
Hook
Gasket
12
Boiling Chamber Lid Knob