Regal Ware W3000 Series Use & Care Manual

Automatic water distiller

Advertisement

Quick Links

AUTOMATIC
WATER DISTILLER
USE & CARE GUIDE
To prevent personal injury or property damage, read and follow the
instructions and/or warnings in this use and care guide.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the W3000 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Regal Ware W3000 Series

  • Page 1 AUTOMATIC WATER DISTILLER USE & CARE GUIDE To prevent personal injury or property damage, read and follow the instructions and/or warnings in this use and care guide.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Important Safeguards ........... 3 .
  • Page 3: Important Safeguards

    IMPORTANT SAFEGUARDS For use with distiller Model No. W3000 Series • Read all instructions before using. • Use electricity safely and wisely, and observe safety precautions when using your distiller. • Be sure power and fan switches are OFF before plugging power cord into outlet.
  • Page 4 performance. Do not attempt to repair the distiller yourself. If servicing should become necessary, please contact your authorized distributor. SPECIFICATIONS The distiller is designed and intended for household use only. This product conforms to WQA S-400 for the stated performance claims. Cycle Production Operating...
  • Page 5: Preparing Your Distiller And Reservoir For Use

    PREPARING YOUR DISTILLER AND RESERVOIR UNPACKING Your distiller has been securely packed to prevent damage during the shipping process. After removing the distiller and reservoir from the box, open the boiling chamber cover and remove all packing material. Properly dispose of distiller base to fully extend rod from the locked shipping position.
  • Page 6: Initial Cleaning

    PREPARING YOUR DISTILLER AND RESERVOIR CAUTION: To prevent personal injury or property damage, do not plug distiller into wall outlet until all parts have been cleaned and properly installed. INITIAL CLEANING Before using your distiller and reservoir for the rst time, follow the steps below.
  • Page 7: Prepare The Carbon Filter

    PREPARE THE CARBON FILTER To prepare the carbon lter, place it in boiling water for ve minutes. Drain excess water from lter. (See page 11.) The same cleaning process should be used whenever a new replacement lter is installed. The boiling process will remove any carbon dust that formed as a result of shipping.
  • Page 8: Reservoir Assembly - Ars2000 - 7 Gallon

    5) Install the prepared post carbon lter cup by following the instructions provided on page 11. Note: If installing an AP2000 W3000 Series Pump Box, please refer to the Pump Box Use and Care Guide (included with your Pump Box) in order to complete the assembly of the reservoir.
  • Page 9: Reservoir Assembly - Ars3000 - 12 Gallon

    7) Install the pr epared post carbon lter cup by following the instructions on page 11. Note: If installing an AP2000 W3000 Series Pump Box, please refer to the Pump Box Use and Care Guide (included with your Pump Box) in or der to complete the assembly of the reservoir.
  • Page 10 Sight Gauge Retaining Ring Black Plastic Jam Nut Sight Gauge Faucet Rubber Washer Reservoir Plug Rubber Washer Mounting Hole 1/4 - 20 x 1/2 Screw Locking Swivel Casters Caster Support Assembly Black Plastic End Cap...
  • Page 11: Installing Post Carbon Filter Cup

    INSTALLING POST CARBON FILTER CUP Your distiller uses a granular activated carbon (GAC) lter as a nal polishing agent to ensure cleaner, fresh tasting drinking water. 1) Place a prepared carbon lter (see page 7) into the supporting backet in the corner of the reservoir.
  • Page 12: Installing The Boiling Chamber

    INSTALLING THE BOILING CHAMBER Your distiller has been shipped with the boiling chamber already in place. If it has been disturbed during shipping follow the simple steps listed below to reinstall the boiling chamber. CAUTION: To avoid personal injury or property damage, be certain distiller is unplugged.
  • Page 13: Water Supply Connection

    WATER SUPPLY CONNECTION The following instructions are for installation on copper tubing. If you have iron, steel, brass, PVC or other pipe providing the cold water supply in your home, consult a quali ed professional for installation. All state, provincial and local laws and regulations must be followed in the installation and use of your distiller.
  • Page 14: Installing The Saddle Valve Connection

    INSTALLING SADDLE VALVE CONNECTION 1) Locate the other end of the long tube and slip on the brass compression nut, threaded toward the cut end of the tube. 2) Slip on the nylon ferrule, narrow end toward the cut end of the tube. The nylon ferrule should be about 1⁄4 inch down the tube.
  • Page 15: Distiller Operation

    DISTILLER OPERATION Your distiller is easy to use. The water level in the boiling chamber is controlled automatically. When connected to the cold water supply line the water will automatically feed into the boiling chamber and shut o when the proper water level is achieved. The condensing fan and the heating element of the boiling chamber are also controlled automatically, resulting in worry-free operation.
  • Page 16: Reservoir

    CAUTION: To prevent personal injury or property damage, only unplug boiling chamber power cord after POWER and FAN switches are turned OFF, distiller is unplugged from the wall outlet and the unit has completely cooled. 3) Remove the rubber gasket from the boiling chamber. Clean the gasket with a mild detergent, rinse and dry thoroughly.
  • Page 17: Pre And Post Carbon Filters

    Carbon FIlters 1) Approximately every two months discard the used post carbon lter cup and replace it with a new one. (See procedure on pages 7 and 11). Do not attempt to reuse the old lter cup. Note: The e ective life of the post carbon lter will var y depending on the amount of distilled water your family uses.
  • Page 18: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Distiller will not POWER switch is not Make sure that the POWER operate. in the ON position. switch is in the ON position and that the unit is plugged into the wall outlet. Page 5 Boiling chamber not Remount boiling chamber.
  • Page 19 TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Heating element Make sure that the unit is Unit not plugged into does not work. wall outlet. plugged into the wall outlet. Boiling chamber power Ensure that boiling cham- cord not plugged in. ber power cord is plugged into receptacle, then push the thermal overload reset switch on the side of the...
  • Page 20: Troubleshooting Guide

    TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE SOLUTION Distilled water The carbon lter is Replace the pre and post has an unusual contaminated. carbon lters. Page 17 taste. Clean the reservoir The reservoir needs following the instructions cleaning. on page 16. Clean boiling chamber . Boiling chamber needs Page 15-16 cleaning.
  • Page 21 With minimum maintenance your distiller will provide convenient continuous operation. Contact your authorized distributor for all warranty, parts and service needs. For additional information, call Consumer Service at 262-626-8623. REGAL WARE, INC. 1675 Reigle Drive Kewaskum, WI 53040 L 2 0 1 0 8 W T ©...

This manual is also suitable for:

W3400 seriesW3500 seriesW3600 seriesW3700 series

Table of Contents