4.0 DEPLOYMENT OF BLITZFIRE

It is the responsibility of the individual fire department or agency to determine physical capabilities and suitability for
an individual's use of this equipment.

4.1 CARRYING WITH AN UNCHARGED HOSE

On a preconnected hoseline the Blitzfire may be carried over the
shoulder with the legs folded as illustrated in figure 4.1.
Figure 4.1 Carrying the Blitzfire on an Uncharged Hose

4.2 ADVANCING WITH A CHARGED HOSE

On a charged hose the Blitzfire may be advanced by holding the valve handle and one of the legs as shown in figure
4.2. Valve handle should be locked in the closed position to keep the valve from inadvertently opening.

5.0 ANCHORING

The nozzle reaction force on the Blitzfire may be as high as 330 lbs - 500 GPM at 175 PSI (150 kg- 2000 LPM at 12
BAR). This nozzle reaction must be restrained to keep the monitor from moving.
The monitor should be anchored from moving by one or more of these methods:
Figure 4.2 Advancing the Blitzfire with a Charged Hose
METHOD
Anchoring by Weight
Anchoring by Spike Holds
Hooking legs on vertical surfaces
Using a tie off strap
RISK of MOVING
High
Medium
Medium
Low