No.
Item
P167
2nd electric current value for
thread clamp (ON duty)
P168
Back-tack solenoid ON
parameter
P169
Back-tack solenoid ON
parameter
P170
Back-tack solenoid OFF
parameter
* Do not change the set values with asterisk (*) mark as they are functions for maintenance. If the standard set value set at the time
of delivery is changed, it is in danger of causing the machine to be broken or the performance to be deteriorated. If it is necessary to
change the set value, please purchase the Engineer's Manual and follow the instructions.
No.
Item
J04
Selection of language for the
audio function
J05
Audio ON/OFF function
J10
Setting of brightness of the back-
light
J11
Energy saving mode
J14
Password
No.
Item
Main software version
N01
Panel software version
N02
N14
ST motor software version
N15
Number of stitches to stop the
grease counter
Description
"ON duty" is set in order to determine the 2nd electric current
value of the thread clamp * Refer to the explanation of operation
of the thread clamp solenoid in the Engineer's Manual for details.
Back-tack solenoid ON parameter
* Refer to the explanation of operation of the back-tack solenoid
in the Engineer's Manual for details.
Back-tack solenoid ON parameter
* Refer to the explanation of operation of the back-tack solenoid
in the Engineer's Manual for details.
Back-tack solenoid OFF parameter
* Refer to the explanation of operation of the back-tack solenoid
in the Engineer's Manual for details.
Description
The language for the audio function is selected with
this function setting item.
1: Chinese
2: English
ON/OFF of the audio guidance is set with this function
setting item.
0: All audio guidance is set to OFF
1: Only the panel operation guidance is enabled
2: All audio guidance is set to ON.
* When this item is set to "1", the audio guidance for
" ③ At the time of operating the sewing machine;
Guidance on the production support"
guidance" p.
25) is placed in OFF.
Brightness of the backlight is set with this function
setting item.
Time to turn OFF the backlight of LCD when the panel
is not operated is set with this function setting item.
0: The backlight is not turned OFF
1 - 20: Time to be elapsed before turning OFF the
backlight
If the password is set to a number other than "0000",
the password entry screen will be displayed before
displaying the function setting screen by pressing the
M switch.
③ At the time of operating the sewing machine
Guidance on the production support
Description
Main software version is displayed with this function
setting item.
Panel software version is displayed with this function
setting item.
Version of the stepping motor control software is dis-
played with this function setting item.
The number of stitches sewn is monitored in order to
notify the operator of the timing of replenishing grease.
Unit: (× 100,000 stitches)
When the grease counter value reaches 800,000,000
stitches, the grease shortage warning "E220" occurs.
When the grease counter value reaches 900,000,000
stitches, the grease shortage error "E221" occurs.
* The grease counter is cleared to "0" (zero).
– 41 –
Level
Setting range
U
S
S
S
Level
Setting range
U
1-2
U
0-2
("4-3. Audio
U
1-3
U
0-20(min)
S
0000-9999
Level
Setting range
U
U
U
S
Default
0-100
69
1-200
25
1-200
40
1-200
10
Default
2
2
3
0
0
Default