LEDs for status display
The following status displays on the NX10.3 provide information about the module state:
LEDs
Color
RDY
Off
Green
Red
Yellow
DP
Off
Green
Red
RESET button
The RESET button is on the front of the module under the cover.
Note
When the pushbutton is actuated, the locally connected drive systems are brought to a
standstill with no feedback to the control. In other words, the drive and control run
asynchronously once the drive has been successfully powered up.
PPU and components
Manual, 05/2015, 6FC5397-2DP40-3BA4
Status
Description
Electronic power supply outside permissible tolerance range
Continuous light
NX10.3 is ready for operation.
Flashing 2 Hz
Writing to CompactFlash card
Continuous light
NX10.3 is presently booting and at least one fault is pending (e.g.
RESET, watchdog monitoring, basic system fault).
Flashing 0.5 Hz
Boot error (e.g. firmware cannot be loaded into the RAM)
Continuous light
Firmware is being loaded into the RAM.
Flashing 0.5 Hz
Firmware cannot be loaded into the RAM.
Flashing 2 Hz
Firmware CRC fault
Electronics power supply outside permissible tolerance range:
NX10.3 is not ready for operation.
Continuous light
CU_LINK is ready for communication and cyclic communication is
running.
Flashing 0.5 Hz
CU_LINK is ready for communication and cyclic communication is not
running.
Continuous light
At least one CU_LINK fault is present.
CU_LINK is not ready for operation (e.g. after switching on).
Anschließbare Komponenten
7.10 NX10.3
247