Name
Parameter
269
Parameter for manufacturer setting. Do not set.
Stop-on contact control
270
selection
Stop-on contact excitation
275
current low-speed multiplying
factor
PWM carrier frequency at
276
stop-on contact
Stall prevention operation
277
current switchover
278 to 283 Parameter for manufacturer setting. Do not set.
286
Droop gain
287
Droop filter time constant
Automatic acceleration/
292
deceleration
Acceleration/deceleration
293
separate selection
Magnitude of frequency
295
change setting
296
Password lock level
297
Password lock/unlock
298
Frequency search gain
Rotation direction detection
299
selection at restarting
338 to 340,
Parameter for manufacturer setting. Do not set.
342, 343
450
Second applied motor
495 to 497,
Parameter for manufacturer setting. Do not set.
500
Communication error
501
occurrence count display
502
Parameter for manufacturer setting. Do not set.
503
Maintenance timer
Maintenance timer alarm
504
output set time
547 to 551,
Parameter for manufacturer setting. Do not set.
555 to 557
Energization time carrying-
563
over times
Operating time carrying-over
564
times
571
Holding time at a start
611
Acceleration time at a restart
653
Speed smoothing control
Regeneration avoidance
665
frequency gain
800
Control method selection
859
Torque current
Input phase loss protection
872
selection
Regeneration avoidance
882
operation selection
Setting
Initial
Parameter
Range
Value
0, 1
0
0 to 300%,
9999
9999
0 to 9, 9999
9999
0, 1
0
0 to 100%
0%
0 to 1s
0.3s
0, 1, 7, 8, 11
0
0 to 2
0
0, 0.01, 0.1,
0
1, 10
0 to 6, 99,
C22 to C25
100 to 106,
9999
199, 9999
1000 to 9999
9999
(0 to 5, 9999)
0 to 32767,
9999
9999
0, 1, 9999
0
∗1
0, 1, 9999
9999
∗2
0
0
0 (1 to 9998)
0
∗3
0 to 9998,
9999
9999
∗4
(0 to 65535)
0
∗5
∗6
(0 to 65535)
0
0 to 10s,
9999
9999
0 to 3600s,
9999
9999
0 to 200%
0
0 to 200%
100
20, 30
20
0 to 500A (0
to ****) ,
9999
9999
∗5
0, 1
1
0, 1, 2
0
Name
Regeneration avoidance
883
operation level
Regeneration avoidance
885
compensation frequency limit
value
Regeneration avoidance
886
voltage gain
888
Free parameter 1
889
Free parameter 2
C0
(900)
C2, C3
(902)
125, C4
(903)
C5, C6
Parameter for manufacturer setting. Do not set.
(904)
126, C7
(905)
(922, 923)
990, 991
Pr.CL
Parameter clear
ALLC
All parameter clear
Er.CL
Faults history clear
Pr.CH
Initial value change list
Differ according to capacities.
6%: 0.75K or lower
4%: 1.5K to 3.7K
3%: 5.5K, 7.5K
2%: 11K, 15K
Differ according to capacities.
5s: 3.7K or lower
10s: 5.5K, 7.5K
15s: 11K, 15K
Differ according to capacities.
6%: 0.1K, 0.2K
4%: 0.4K to 7.5K
2%: 11K, 15K
The initial value differs according to the voltage class. (200V class/400V
class)
The range differs according to the Pr. 71 setting.
The setting cannot be changed through the FL remote communication.
PARAMETER LIST
Setting
Initial
Range
Value
400VDC/
300 to 800V
780VDC
0 to 10Hz,
6Hz
9999
0 to 200%
100%
0 to 9999
9999
0 to 9999
9999
0, 1
0, 1
0, 1
∗4
0
0
0
23