PARAMETER LIST
Name
Parameter
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
61
Reference current
Reference value at
62
acceleration
Reference value at
63
deceleration
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73, 74
Parameter for manufacturer setting. Do not set.
Reset selection/PU stop
75
selection
77
Parameter write selection
∗6
Reverse rotation prevention
78
selection
79
Parameter for manufacturer setting. Do not set.
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
Speed control gain (Advanced
89
magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
96
Auto tuning setting/status
117 to 134,
Parameter for manufacturer setting. Do not set.
145, 146
22
Setting
Initial
Parameter
Range
Value
0 to 60s
1s
0, 1, 2, 3
0
0, 9
0
0 to 500A,
9999
9999
0 to 200%,
9999
9999
0 to 200%,
9999
9999
0 to 5
0
0 to 400Hz
60Hz
0 to 10, 101
0
to 110
0.1 to 360s
1s
0
0
0 to 30%
0%
0, 1, 3 to 6,
13 to 16, 23,
24, 40, 43,
0
44, 50, 53,
54
0 to 15
1
0 to 3, 14 to
14
17
0, 1, 2
0
178 to 184,
190 to 192,
0, 1, 2
0
232 to 239
0.1 to 15kW,
9999
9999
2, 4, 6, 8, 10,
9999
9999
0 to 500A
(0 to ****),
9999
9999
∗5
200V/
0 to 1000V
400V
∗4
10 to 120Hz
60Hz
0 to 200%,
9999
9999
0 to 50Ω
(0 to ****),
9999
9999
∗5
0 to 50Ω
(0 to ****),
9999
9999
∗5
0 to 1000mH
(0 to 50Ω, 0 to
9999
****), 9999
∗5
0 to 1000mH
(0 to 50Ω, 0 to
9999
****), 9999
∗5
0 to 100%
(0 to 500Ω, 0
9999
to ****), 9999
∗5
0, 1, 11, 21
0
Name
Acceleration/deceleration time
147
switching frequency
150
Output current detection level
Output current detection signal
151
delay time
152
Zero current detection level
153
Zero current detection time
Stall prevention operation
156
selection
157
OL signal output timer
160
User group read selection
Frequency setting/key lock
161
operation selection
Automatic restart after
162
instantaneous power failure
selection
Stall prevention operation level
165
for restart
168, 169 Parameter for manufacturer setting. Do not set.
170
Watt-hour meter clear
171
Operation hour meter clear
User group registered display/
172
batch clear
173
User group registration
174
User group clear
Parameter for manufacturer setting. Do not set.
240
Soft-PWM operation selection 0, 1
241
Parameter for manufacturer setting. Do not set.
244
Cooling fan operation selection 0, 1
245
Rated slip
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
Earth (ground) fault detection
249
at start
250
Stop selection
Output phase loss protection
251
selection
255
Life alarm status display
Inrush current limit circuit life
256
display
Control circuit capacitor life
257
display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
261
Power failure stop selection
267
Parameter for manufacturer setting. Do not set.
Monitor decimal digits
268
selection
Setting
Initial
Range
Value
0 to 400Hz,
9999
9999
0 to 200%
150%
0 to 10s
0s
0 to 200%
5%
0 to 1s
0.5s
0 to 31, 100,
0
101
0 to 25s,
0s
9999
0, 1, 9999
0
0, 1, 10, 11
0
0, 1, 10, 11
1
0 to 200%
150%
0, 10, 9999
9999
0, 9999
9999
9999, (0 to
0
16)
0 to 999,
9999
9999
0 to 999,
9999
9999
1
1
0 to 50%,
9999
9999
0.01 to 10s
0.5s
0, 9999
9999
0, 1
0
0 to 100s,
1000 to
9999
1100s, 8888,
9999
0, 1
1
(0 to 15)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1 (2, 3, 8,
0
9)
0, 1, 2
0
0, 1, 9999
9999