Download Print this page

Omron ZFV-C Command Reference Manual page 10

Smart sensor, non-procedural communication
Hide thumbs Also See for ZFV-C:

Advertisement

Parameter List (ZFV-C)
Position (POSITION)
Unit No.
2
2
2
2
2
2
2
2
2
Count (COUNT)
Unit No.
2
2
2
2
2
2
2
2
2
2
ZFV-C
8
Non-procedural Communication Command Reference
Parameter No.
Parameter
0
Judgment
1
Measured value
2
Measurement result
maximum value
3
Measurement result
minimum value
4
Measurement result
average value
20
Measurement count
21
NG count
22
Fault rate
38
Threshold
Parameter No.
Parameter
0
Judgment
1
Measured value
2
Measurement result
maximum value
3
Measurement result
minimum value
4
Measurement result
average value
20
Measurement count
21
NG count
22
Fault rate
38
Upper limit value
39
Lower limit value
Setting range/output range
-2: measurement off
-1: NG
0: OK
0 to 468
0 to 468
0 to 468
0 to 468
0 to 9999999
0 to 9999999
0 to 99.999
0 to 468
Setting range/output range
-2: measurement off
-1: NG
0: OK
0 to 128
0 to 128
0 to 128
0 to 128
0 to 9999999
0 to 9999999
0 to 99.999
0 to 255
0 to 255
Remarks
DATAGET compatible
DATASET/DATAGET
compatible
Remarks
DATAGET compatible
DATASET/DATAGET
compatible

Advertisement

loading