Download Print this page

Electrical Connections; Electrical Specifications; Operating Instructions; Disassembly And Assembly - JABSCO 37010 Series Operating Instructions

Electric marine toilet

Advertisement

ELECTRICAL CONNECTIONS - Select a location for
the switch and instruction plate, making sure wire leads
from both the toilet and power source can be routed to
the switch. Ensure the panel where installing switch is no
more than 1" thick. Drill a 5/8" mounting hole and install
switch and instruction plate. Use stranded copper wire of
the correct size (determined from the electrical specifi-
cations chart) to connect one side of the switch to the
positive power source. An appropriate size fuse or equiv-
alent circuit breaker (determined from electrical specifi-
cations chart) must be installed in the positive power
lead within seven inches of the power source. Connect
the other side of the switch to the orange (positive) motor
lead. Connect the black (negative) motor lead to the
negative side of the battery or grounded buss bar.
NOTICE: Correct motor polarity (orange to positive,
black to negative) is important. Reverse polarity can
damage motor and void warranty. Full voltage at the
motor is required to properly operate the Electric Toilet.
The toilet must be wired in a circuit independent of all
other accessories.

ELECTRICAL SPECIFICATIONS

AMP
FUSE
WIRE SIZE PER FEET OF RUN*
VOLTAGE
DRAW
SIZE
0'-10'
12 Vdc
16
25
#12
24 Vdc
8
15
#16
* Length of run is total distance from power source to product and back to ground.

OPERATING INSTRUCTIONS

Make sure inlet and outlet seacocks are all open; push button
to operate. Operate until bowl is completely flushed and
discharge pump has scavenged water from bottom of bowl.
The Jabsco electric marine toilet will provide years of trou-
blefree service if properly used. It will handle waste and toi-
let tissue. It will NOT handle rags, sanitary napkins or hard
solid objects.
If bowl does not pump out and begins to fill, partially close
inlet valve until bowl is cleared and completely pumped
out. Then operate for a few seconds with both valves open
to clear entire toilet and discharge system. For maximum
safety, when toilet is not in use or vessel is unattended,
close both the inlet and discharge seacocks.
To drain for winter lay-up, close inlet valve and operate for
a few seconds until all water is pumped out.
After long periods of non-use, toilet and pump may dry out.
To ease initial start-up, put about one quart of water in bowl
and let stand awhile before initial use.
DISASSEMBLY
WARNING
!
Flood hazard. Close inlet and outlet
seacocks prior to disassembling toilet.
Failure to do so can result in flooding
which can cause loss of property and life.
Disconnect pumping inlet and discharge hoses. Remove
four screws, Key No. 25, pull out complete motor, pump
and macerator assembly. If assembly does not slide out
www.PumpAgents.com
10'-15'
15'-25'
25'-40'
40'-60'
#10
#10
#8
#14
#12
#10
#10
PumpAgents.com - buy pumps and parts online
easily, push forward and pull back sharply several times to
free macerator housing from base.
Remove discharge port, Key No. 12, and joker valve.
Unscrew chopper plate, Key No. 14, by turning counter-
clockwise, facing plate. Prevent shaft from turning by plac-
ing screwdriver in discharge port and locking centrifugal
impeller blade. Remove macerator housing. Loosen
impeller set screw and slide impeller off motor shaft.
Remove four flathead screws and two washers, Key Nos.
20, 21, & 22. Remove the plastic wearplate, Key No. 23,
with sealing sleeve, Key No. 19, and gasket, Key No. 26.
Slide pump assembly off motor shaft. Replace all worn or
damaged parts, clean remaining parts.
ASSEMBLY
Press seal into body with lip facing impeller; be careful
not to cock seal in bore. Install pump body on motor and
position on register. Lubricate impeller bore with pump
grease and install impeller. Position the gasket against
the body and install the wearplate ensuring the two plas-
tic sealing washers are under the heads of the top and
bottom screws. NOTE: The current plastic wearplate
supercedes the earlier brass wearplate and with it the
stainless steel wearplate is no longer used. Slide the
rubber sealing sleeve on the motor shaft and push it into
#6
its recess in the wearplate. Relocate centrifugal impeller
on shaft, about 1/8" from the wearplate, and tighten set
screw. Place macerator housing over shaft and centrifu-
gal impeller, put lock washer on end of shaft and screw
chopper plate on shaft and tighten. Install O-ring in O-
ring groove in wearplate surface, a little grease will help
hold in place, make sure inside body surfaces are clean,
line up slot in base with key on macerator housing, slide
pump assembly into base and tighten with the four
screws. Turn motor on for one or two seconds to be sure
centrifugal impeller is free.
ATMOSPHERE
37068-0000
SOLENOID
TO
NEGATIVE
TO
POSITIVE
TO
NEGATIVE
DISCHARGE TO
HOLDING TANK
MOUNTING
BRACKET
VENT TO
VIEW A
TO VENTED
LOOP
ELECTRICAL
CONNECTIONS
VIEW A
VENTED
PUSH BUTTON
LOOP
SWITCH
INLET
WATER
LINE

Advertisement

loading

This manual is also suitable for:

37010-000037010-009037010-109037010-100037010-000637010-1006 ... Show all