IBM 3274 51C Maintenance Information page 22

Table of Contents

Advertisement

I
Use Test XX/4 to reset the summary error total.
Example C: (Machine configured for 8 Category A and
4
Category B devices)
,Category A device 0
I
,Category B device
0
Line 1: 01234567
8901
Line 2: 10XXXIli 1111
Line 3: dddidddd
pppp
Line 4:
Line 5:
Line 6:
++++
Line 7:
*
*
+ ++ +
Line 8: 0000 0001 0000 0000 0000
Line 1 shows coaxial port addresses (0-11). In this
example the 3274 is configured for 12 devices (8 Cate-
gory
A
displays and 4 Category B printers). Category A
devices are always shown first. Printer and Category B
devices are then shown separated by two spaces.
Line 2 shows the status of each device, where:
1
=
device powered on
o
=
device recognized as powered off
=
device recognized as disabled because of control-
unit-detected errors
x
=
unassigned port (Note 1)
Line
3
shows the type of device attached, where:
d
=
display
p
=
printer
I
=
other
=
never initialized
=
display terminal (3290)
Line 4 shows a summary of coaxial errors, where:
=
no errors
= 1-10
errors
I
= 10-20
errors
*
= 20
or more errors
Line 5 shows a summary of device errors, where:
=
no errors
= 1-10
errors
I
= 10-20
errors
*
= 20
or more errors
Line 6 shows a summary of sessions bound (this line will
appear only for SNA attachments), where:
+
=
session bound
Blank
=
no session bound
Line 7 shows a display of dialed (X.21 switched only),
where:
##XXXX (up to 32 characters) dialed number entered
by the keyboard
## - - - - 0000
=
direct call
##
- - - -
=
incoming call
2-10
line 8 shows a summary of 3274 checks:
AABB CCDD EEFF GGHH JJKK
0000
0000
0000
0000
0000
Counter
AABB
CCDD
EEFF
GGHH
JJKK
Notes:
Meaning
Summary of
all
machine checks·
Summary of
all
communication checks
Summary of all program checks
SDLC test commands received
SDLC test commands sent
(Maximum counter values are FFFF)
1. Customized with individual port addressing. Allows
unassigned (unused) physical port locations between
used coaxial port locations. Applies to configuration
Support D.
2.
When 3290 displays are attached, the Category B
adapters are not installed.
f.
Test /B Device Address Assignment Table (Model 51 C)
If individual port addressing was used during
customization, the physical port and logical device
addresses can be displayed using the following /B Test.
Refer to Figures 2-7,2-8, and 2-9.
Do the following at any display except a 3290:
(1) While holding the ALT key, press the Test Request
key.
(2) Key in /B.
(3) Press the Enter key. The minus function (x--F) is
r.eturned if the display does not have a large enough
screen size.
(4) To exit the test mode, press and hold the ALT key
and press the Test key.
The format will be displayed as shown in Figure 2-8 or
2-9.
If this step did not fix your problem or
it
did not
apply, go to Step 6.
Notes:
1. The address table is displayed if the individual port
assignment table was used during customization with
Configuration Support D.
2. If customization was performed using sequential port
addressing (sequence number 112), the /B Test will not
run.
3. Using individual port addressing automatically assigns
the device logical addresses and allows unassigned
(unused) physical port locations between used coaxial
port locations.

Advertisement

Table of Contents
loading

This manual is also suitable for:

3274 52c

Table of Contents