Use for Errors during IML
/
, . . - - - - - - - - - - '
This figure shows error codes (fail codes) correlated to all possible card failures in order of probability. To convert the card number to actual
I
board/card socket location, see Figure A-12 (FO-3, FO-5) or Figure 1-7. If codes 0101,0110, and 0111 are alternating, use the flashing code
as the failure indicator.
U
IML
Fail
Code
Card Reference Number
0000
1
7,8,9,3,1,2,4,2 5 ,2 6 ,2 11 ,12,13,27,10,21,
I
14,25
0001
1
3,7,4,2
0010
4
1Q, 22, 27, 26, 24,11,12,13,14,9,21
0011
4
12,13,14,24,28,10
0100
4
12,13,28
0101
5
1,2,3,4,2 5,2 7,9
Do this first
0110
5
13, 14
0111
5
13, 14
6
w/o 2400-,4800-, or
_or
9600-bps I ntegrated Modem feature
0111
5
With 2400-,4800-, or 9600-bps Integrated
Modem feature
1000
4
24,25,26,27,30
1001
4
21
1001-
1110
7
1001-
1010
7
1110
1
1010
4
10,13,8 1 ,2- Do this first
1011
4
11
1101 4
None
11114
--------------------------
1 The 8 4 2 1 indicators are continuously displaying this code.
2 With some part numbers it is possible to plug this card in back·
wards. To ensure the correct plugging position. see Figure A-II.
1
3 II. during use of a customized system diskette. a successful
AL T 1 IML can be performed, the operational code was
properly loaded from the diskette. This eliminates the
diskette, cables, motor rotation. fuses, and voltage as
possible causes.
4
Code is usually flashing (alternately
on/olll.
Figure 2-3. Failure Code to Card or MAP Entry
~
~
Map, Reference Figure, and Notes
Go to MAP A20 if card-swapping did not fix problem or if not all
cards are available.
Check for proper diskette.
3
Go to MAP A40 if problem still exists.
3
Check for loose card in socket Y6. Go to MAP A50.
Go to MAP A50.
See Figure 2-4.
See Step 8 in this chapter and Chapter 5, paragraph 5.3 (Wrap Testl.
See Chapter 5, paragraph 5.3 (Wrap Test).
~
See Chapter 5, paragraph 5.4-.5.6.
Go to MAP A90 (Model 51 Conly).
The customer security administrator must reload the master key
after the card is removed and replaced. This procedure and the
associated encrypt/decrypt information are contained in Chapter 6.
The 3274 does not have the required storage. Verify storage cards.
See Figure 2-4. Verify Customization Response 113. Occurs for
Configuration Support 0 and above.
Incorrect system diskette or load diskette for Model 51 hardware.
Verify system diskette or load diskette. Occurs for Configuration
Support 0 and above.
The 3274 control storage does not match customization response
113. Occurs when performing an AL T-1 operation. Verify that
storage cards are correct. See Figure 2-4.
Change diskette drive file control card (card No. 22) and system
diskette.
9
If the board has been replaced, verify that board wiring has been
properly modified. See Figure 4-14.
Uncustomized system diskette.
Operational code failed to load correctly. Try spare system diskette.
I
s Code is usually flashing, but may alternate between a
flashing and a continuous code.
6 If code 0111 is displayed continuously, replace card numbers 24.
25,26,
and
27.
7 The two codes are alternating.
8
II HPCA installed.
9 This code can occur during any IML sequence or during
operational code load.
Chapter 2. Subsystem Problem Isolation Procedure