Troubleshooting Guide; Kombimotor - Stihl KMA 130 R Instruction Manual

Hide thumbs Also See for KMA 130 R:
Table of Contents

Advertisement

Available languages

Available languages

24 Troubleshooting Guide

24 Troubleshooting Guide

24.1 KombiMotor

Always remove the connecting cord before carrying out any inspection, cleaning or maintenance.
Condition
LEDs on
Battery
KombiMotor does not
start when switched
on.
1 LED flashes
green.
STIHL AR only:
Additionally,
four long beeps
are emitted.
1 LED glows
red.
4 LEDs flash
red.
STIHL AR only:
Additionally, a
rapid
succession of
short beeps is
emitted.
3 LEDs glow
red.
3 LEDs flash
red.
0458-805-8621-A
Cause
Remedy
No electrical contact
► Remove the connecting cord, @ 15.2.
between
► Visually check the electrical contacts in the socket.
KombiMotor and
► Reinsert the connecting cord, @ 15.1.
battery.
► If the KombiMotor still does not start, clean the contact
surfaces on the connecting cord, @ 22.2.
Battery has low
► Charge the battery as described in its instruction manual.
charge.
Battery too hot / too
► Allow the battery to warm up or cool down gradually at
cold.
ambient temperatures of about 50 °F to 68 °F (10 °C to
20 °C).
Malfunction in
► Remove and reinsert the connecting cord, @ 15.
battery.
► Switch on the KombiMotor, @ 16.1.
► If the LEDs continue to flash, do not attempt to use.
The battery has a malfunction and must be replaced.
KombiMotor too hot. ► Allow the KombiMotor to cool down.
Malfunction in
► Remove and reinsert the connecting cord, @ 15.
KombiMotor.
► Switch on the KombiMotor, @ 16.1.
► If the LEDs still flash, do not attempt to use.
The KombiMotor has a malfunction and must be checked by
a servicing dealer.