Termination of the HVSC Plus Lower End

Please refer to LTERMKIT-MK3 supplied with the HVSC Plus cable.
Check the cable first prior to performing the termination to ensure the use of the correct lower
termination kit.
Connection of Factory Pre-Terminated HVSC Plus (Upper End) to
Guardian Plus
The tools required for the installation of the factory completed upper termination include:
Sharp knife
PH2 Phillips head screw driver
3 mm Hex/Allen Key
Proceed as follows:
1. Remove the protective packaging from the cable and upper terminated end section, taking
care not to cut the cable or associated upper termination.
2. Using a Phillips Head screwdriver, remove the M6 Phillips Head screw holding the mast
butt adaptor (if fitted) to the lower connector and retain both the screw and the mast butt
adaptor.
3. Feed the HVSC Plus cable through the FRP support mast.
4. Slide the black plastic mast butt adaptor back onto the lower finial connector, line up holes
and screw the Phillips Head screw into position tightly. Next, screw the mast butt adaptor
into the Guardian Plus terminal and tighten the M6 Grub screw at the base of the terminal
to lock the assembly.
Figure 28.
32