NIBE UPLINK
Connect the network connected cable (straight, Cat.5e
UTP) with RJ45-contact (male) to RJ45 contact (female)
on the rear of the heat pump.

NIBE F470

EXTERNAL CONNECTION OPTIONS
F470 has software-controlled AUX inputs and outputs
on the input board (AA3), for connecting the external
switch function or sensor. This means that when an
external switch function (the switch must be potential-
free) or sensor is connected to one of six special con-
nections, this function must be selected for the correct
connection in menu 5.4.
soft in/outputs 5.4
activate temp lux
For certain functions, accessories may be required.
Selectable inputs
Selectable inputs on the input board for these functions
are:
AUX1
AUX2
AUX3
AUX4
AUX5
AA3-X6
The example above uses the inputs AUX1 (X6:9-10) and AUX2 (X6:11-
12) on the input board (AA3).
Selectable output
A selectable output is AA3-X7.
Caution
Some of the following functions can also be
activated and scheduled via menu settings.
POSSIBLE SELECTION FOR AUX INPUTS
Temperature sensor
Temperature sensor can be connected to F470. Use a
2-core cable of at least 0.5 mm² cable area.
Available options are:
• room sensor (RTS 40)
Chapter 5 | Electrical connections
block heating
not used
not used
not used
alarm output
AA3-X6:9-10
AA3-X6:11-12
AA3-X6:13-14
AA3-X6:15-16
AA3-X6:17-18