HP E2494A Installation Manual page 9

Probe adapter for the intel pentium ii mobile processor
Table of Contents

Advertisement

To connect to the target system
Connecting to the Pentium II Mobile Processor mounted on Intel's
Instrumented Interposer board
To protect your equipment, remove the power from both the HP E2487A
C A U T I O N
Preprocessor Interface and the target system before you make or break
connections.
If you are already using an Instrumented Interposer board, remove
1
the Instrumented Interposer board from the target system. If you are
not already using an Instrumented Interposer board, remove the
microprocessor from the target system and plug it into the
Instrumented Interposer board.
Connect the HP E2487A preprocessor interface cables to the
2
HP E2494A probe adapter, as shown on page 4.
Connecting the preprocessor interface cables to the probe adapter after the
C A U T I O N
probe adapter is already connected to the interposer board may exert
excessive stress on the interposer board and the probe adapter. Excessive
stress can damage the interposer board and/or the probe adapter.
Loosen the adjustment screws to ensure that there will be adequate
3
clearance once you connect the probe adapter to the Instrumented
Interposer board.
8