8.3.1.1 General
(buttons, initialization, alerts, HF Response Threshold, ...).
This sound is the one you hear when a conductive material is detected.
value, the software will make a detection sound. The default threshold is set to 300.
is reached, you need to initialize the probe every minute or before each reading. After the
probe is ready, it is possible to set the time between two initializations. The default time is
one minute. Otherwise, you could also set the time for either 5, 10, 15, 30 or 60 minutes.
The new time set will be activated after the next initialization.
8.3.1.2 Connection defines the type of connection (Bluetooth or Serial cable) and the
Bluetooth device to use.
8.3.2 Help offers the links for viewing instruction manuals in three languages (English, French and
Spanish).
8.3.3 About us shows the versions of the Android software and the MPP Probe firmware.
8.3.4 Exit allows to completely exit from the software.
On Android platform an application can stay in background when you press BACK or HOME
button on your Android device.
Use Exit function to be sure to completely exit from GDD MPP software releasing
communication channel and all used memory.
8.4
Reading mode (see Section 9 – Reading Modes).
8.5
Probe battery
The Probe battery indicator starts to flash RED when the probe battery is LOW.
You can also verify the probe battery state with the Bl button on the probe.
Instrumentation GDD Inc.
Enable Sound activates/deactivates all kind of sound notifications in the software
Enable HFR Threshold activates/deactivates the sound on HF Response Threshold.
HFR Threshold defines the HF Response Threshold. On exceeding this HF Response
Initialization Time defines the time interval between required initializations.
Remember: it takes at least 40 minutes for the probe to warm-up. Before that time