Notes Regarding Attaching The Inverter To The Wall Bracket; Attaching The Inverter To The Wall Bracket - Fronius Primo Installation Instructions Manual

Grid-connected inverter
Hide thumbs Also See for Primo:
Table of Contents

Advertisement

Notes regarding attaching the inverter to the wall
bracket
Attaching the in-
The side sections of the housing lid are designed to function as holding and carrying han-
verter to the wall
dles.
bracket
For safety reasons, the inverter is fitted with a latch that prevents the inverter from
being swung into the wall bracket unless the DC main switch is switched off.
► Never attach the inverter to the wall bracket or swing it in unless the DC main switch is
► Never use force to attach the inverter or swing it in.
The fastening screws in the data communication area of the inverter are used for securing
the inverter to the wall bracket. Correctly tightened fastening screws are a prerequisite if
proper contact is to be established between inverter and wall bracket.
If the fastening screws are not tightened correctly, then the inverter is at risk of be-
ing damaged.
Fastening screws that are not correctly tightened can result in arcs occurring when the in-
verter is in operation, which in turn can cause fires. Always use the specified torque when
tightening the fastening screws.
20
NOTE!
switched off,
CAUTION!