4 Diagnostics

There are three light emitting diodes (LEDs) on the electronic circuit board:
 Red and green – on the right;
 Red – on the left.

4.1 Initial startup

 When power is supplied (i.e. after connecting the battery) the red and greed LEDs on
the right glow continually;
 After several seconds the red LED on the right goes out, the green LED on the right
glows continually, and the red LED on the left start blinking quickly;
 When the weather station connects to the GSM network, the green LED on the right
goes out, and the red LED on the left starts blinking at longer intervals.

4.2 Data transmission

 When the weather station starts transmitting data, first the red LED, then the green
LED on the right start glowing;
 When the device stops transmitting data, first the green LED on the right goes out,
then the red LED on the right goes out.

4.3 No GSM coverage

 When the device cannot connect to the GSM network, the red LED on the left blinks
quickly, and both LEDs on the right glow continually;
 The weather station tries to connect to the GSM network three times one after the
other. If it fails, it tries to connect again after one hour.

4.4 No connection to the server

 When power is supplied the red and the green LEDs on the right glow continually,
after several seconds the red one goes out, the green one glows continually, and the
red LED on the left starts blinking quickly. When the device connects to the network,
the green LED on the right goes out, and the red LED on the left start blinking at longer
intervals;
 Then the data transmission itself starts – first the red LED on the right then the green
LED on the right start glowing. The red LED on the right stops glowing after the
weather station stores the reading from the sensors, and the green LED on the right
remains glowing continually – this means that the device cannot connect to the server
and send the data to it;
 If you encounter this situation, please contact the Meteobot® support team at
tech@meteobot.com.