Minimum load adjustment.
Press [▼] button until minimum load is reached.
Display message
Water heater is activated and operates at service mode at minimum.
By setting screw [3], adjust the gas valve to obtain the CO
Decrease CO
percentage
2
Increase CO
percentage
2
Repeat adjustments:
Check again at maximum load and adjust if necessary.
Check again at minimum load and adjust if necessary.
Repeat previous steps until measurements match shown in 20.1.2.
Switch the top burner off (press service button).
20.2.3

CHECKING AND ADJUSTING THE BOTTOM BURNER

On the right control panel, go to service mode (press [SERVICE] button for 4 seconds). Make sure that only the bottom burner is on:
the green LED on the left panel (top burner) should be off. Also check that the fan of the top burner is not running: the error message
"NRV or fan fault" should not be on the display of the left panel.
Set the load at maximum by pressing the [▲] button.
Measure CO
in the lower measuring hole (bottom burner).
2
Adjust the CO
within ± 0.1% according to shown in 20.1.2 using key [2].
2
Set the load at minimum by pressing the [▼] button.
Adjust the CO
within ± 0.1% according to shown in 20.1.2 using key [3].
2
Check again at maximum load and adjust if necessary.
Check again at minimum load and adjust if necessary.
Repeat previous steps until measurements match shown in 20.1.2 .
Switch the bottom burner off (press [SERVICE] button).
20.2.4

CHECKING BOTH BURNERS

To switch both burners on at the same time: switch to service mode, set one burner at 50% load using the [▲] and/or [▼] buttons. While this
burner is on, switch the other burner to service mode (press [SERVICE] button for 4 seconds). After start-up, set it also at 50% load.
To set both burners at maximum load, press [▲] buttons on both panels simultaneously.
Measure CO
in the upper measuring hole (top burner); a tolerance of -0.1 to + 0.3% of the shown in 20.1.2 value is acceptable. Note
2
down this value.
Measure CO
in the lower measuring hole (bottom burner); a tolerance of - 0.3 to +0.1% of the shown in 20.1.2 value is acceptable.
2
Note down this value.
Calculate the average of these two measurements: add the upper and lower values and divide by two.
If this average CO
deviation is larger than ± 0.1%, check and re-adjust burners separately again.
To change to minimum load, press [▼] buttons on both panels simultaneously.
Check CO
for the minimum load: measure CO
2
table16.1 value is acceptable. Note down this value.
Measure CO
in the lower measuring hole of the bottom heat exchanger; a deviation down to - 0.3% of the shown in 20.1.2 value is
2
acceptable. Note down this value.
Calculate the average of these two measurements: add the upper and lower values and divide by two.
If this average CO
check and re-adjust burners separately again.
If measurements at maximum and minimum match shown in 20.1.2 within ± 0.1%, adjustment is completed.
Switch burners off (press [SERVICE] buttons on both panels).
W A
>
>
>
at maximum matches shown in 20.1.2 within ± 0.1%, proceed with the next step: checking at minimum load. If the
2
at minimum matches shown in 20.1.2 within ± 0.1%, adjustment is correct. If the deviation is larger than ± 0.1%,
2
R :
S
T
R
H
T
1
2
3
.
4
value shown in 20.1.2
2
C O 2
[ 3 ]
C O 2
[ 3 ]
in the upper measuring hole of the top heat exchanger; a deviation up to + 0.3% of the
2
e
r
v
i
c
e
°
C
(
1
2
3
.
Turn key [3] left (counter clockwise)
Turn key [3] right (clockwise)
3
0
%
4
°
C
)
97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ttw410Ttw580

Table of Contents