Download Print this page

Tools And Supplies Needed - Interlogix AP750W Installation Instructions Manual

Wireless pir motion sensor

Advertisement

Figure 1:
Overhead View Walking Across Detection
Pattern
Do not mount the sensor near duct work or other large
metallic surfaces which may affect the RF signals (see
"Final Testing" on page 4). Actual acceptable transmitter
range should be verified for each installation.
Windows should be closed in any area which has an
armed motion sensor.
The cardboard under-crawl mask installed at the factory
(see Figure 2) blocks coverage within 5 feet of the
sensor.
Figure 2:
Cardboard Under-crawl Mask Location
Note:
The cardboard under-crawl mask should remain
installed when sensor jumper J1 is set to the BI
position. See the section "Setting the Sensor
Coverage Area and Sensitivity" for complete
information on sensor jumper settings.
2 / 7
For installations where pets are present, mount the
sensor upside down about 3.5 feet above the floor (see
Figure 3). Leave the factory-installed under-crawl mask
in place to block any detection pattern directed at the
ceiling.
Figure 3:
Pet Alley Application

Tools and Supplies Needed

Phillips screwdriver
Anchors and screws for mounting (included)
Masks (included)