The ShatterPro
omnidirectional glassbreak sensor (60-873-
95) provides 360 degree coverage. It can be mounted on the
ceiling, or on the opposite wall, or on adjoining walls. It has a
range of up to 20 feet for glass panes 1' x 2' (0.3 m x 0.6 m)
or larger.
Figure 1:
ShatterPro Glassbreak Sensor
The maximum detection range is 20' (6 m) for plate,
tempered, laminated and wired glass. For armor-coated
glass, the maximum detection range is 12' (3.65 m).
Coverage is measured from the sensor to the point on the
glass farthest from the sensor (see D and D' in Figure 2
below). See Specifications on page 4 for recommended
glass thickness.
Figure 2:
Optimum Performance Zone
Note: ShatterPro may not consistently detect cracks in
glass, or bullets that break through the glass.
Glassbreak sensors should always be backed up by
interior protection.
© DDMONYY UTC Fire & Security. All rights reserved.
Glassbreak Sensor

Installation Guidelines

For best detection, avoid installing in rooms with lined,
insulating, or sound deadening drapes or rooms with closed
wooden window shutters inside.
Do not use sensor near air compressors. A blast of
compressed air may cause a false alarm.
Avoid stairwells, glass booths, and all rooms smaller
than 10' x 10' (3 m x 3 m).
The Pattern Recognition Technology™ of the
ShatterPro ignores most false alarm sounds. Some
sounds can duplicate the glass break pattern the
ShatterPro detects, however, so the ShatterPro works
best in rooms with only moderate noise. Avoid rooms
where white noise, such as a fan, is present. Avoid
rooms with noisy areas or multiple noise sources such
as small kitchens or bathrooms, garages, etc.
Note: For glass break protection in these applications
(where ShatterPro is not appropriate), use shock
sensors on the windows or window frames.
Avoid adding (learning) the sensor into 24-hour sensor
groups, where the sensor will be armed even when the
room is in use. Like a motion detector, a glass break
sensor may be tripped when occupants are in the
protected area. Adding the ShatterPro to a perimeter
sensor group, which is armed only when the perimeter
doors and windows are armed, will help prevent false
alarms.
The device may not work properly in humid rooms. Do
not install it in such conditions.

Tools needed

Phillips screwdriver
A 5709C-W hand-held tester
Note: Please see page 6 for important product safety,
warranty, limitation of liability, and disclaimer
information.
1 / 6
P/N 466-5401 • REV B • 9MAY18

Advertisement

loading

Summary of Contents for Interlogix ShatterPro

  • Page 1: Installation Guidelines

    See Specifications on page 4 for recommended sensor may be tripped when occupants are in the glass thickness. protected area. Adding the ShatterPro to a perimeter sensor group, which is armed only when the perimeter Figure 2: Optimum Performance Zone doors and windows are armed, will help prevent false alarms.
  • Page 2: Installation

    IMPORTANT: DO NOT EXCEED THE 20' MAXIMUM most false alarm sounds, including glassbreak testers, so DETECTION RANGE OF THE the ShatterPro must be set to “test mode” during the SHATTERPRO. While the sensor may following procedure (see step 2). When the sensor is in test...
  • Page 3: Testing The System

    Listen for status beeps (or a voice message) to indicate ShatterPro and hold down the test button (see Figure 5: that the panel is receiving transmissions from the sensor Testing the ShatterPro on page 2).
  • Page 4: Specifications

    Specifications Feature Description All 319.5 MHz Learn Mode™ panels; All Caddx 319.5 MHz panels Compatibility Dimensions 4.25" (108 mm) length 3.12" (79.24 mm) width 1.22" (30.98 mm) depth Operational voltage 2.6 to 4.5 VDC 26 A typical average Current draw Battery life 5 years average Batteries...
  • Page 5: Regulatory Information

    PROTECTION WILL BE PROVIDED, OR THAT THERE WILL BE NO DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE AS A RESULT. WHILE INTERLOGIX UNDERTAKES TO REDUCE THE PROBABILITY THAT A THIRD PARTY MAY HACK, COMPROMISE OR CIRCUMVENT ITS SECURITY PRODUCTS OR RELATED SOFTWARE, ANY SECURITY PRODUCT OR SOFTWARE MANUFACTURED, SOLD OR LICENSED BY INTERLOGIX, MAY STILL BE HACKED, COMPROMISED AND/OR CIRCUMVENTED.
  • Page 6: Contact Information

    IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS SECURITY PRODUCTS AND RELATED SOFTWARE. INTERLOGIX FURTHER DISCLAIMS ANY OTHER IMPLIED WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY ANY STATE.