Regulations - Master Spas INT H2X CHALLENGER 19D Owner's Manual

Table of Contents

Advertisement

REGULATIONS

Below are important requirements that you should be aware of prior to using and operating your
swim spa per European Standard EN 17125:2018.
MEANS OF ACCESS AND SWIM SPA ACCESSORIES
The steps in the swim area can be used to access the spa side with dual water body models such as
Trainer 19, Challenger 19 and Momentum.
All accessories that are supplied shall be safe and compatible with the swim spa as required by
section 4.3 of EN17125. The user can only use accessories exclusively provided by the swim spa
manufacturer (i.e. Master Spas manufactured insulating cover) for safety reasons (section 6.1 d).
Means of access is not provided with the swim spa. Accessories necessary for means of access
must meet European standard EN 17125. The type of means of access to the swim spa must be
considered (ingress and/or egress where not obvious). Access means can be either secured or
unsecured. See Accessory Manufacturer Specifications for the following:
• the commercial name or reference;
• an indication of the maximum allowable weight permitted on the means of access;
• illustrations repeating the overall dimensions of the product;
• stepping height and width of the wall, if appropriate for ingress and egress;
• if appropriate, any indication concerning the construction of onsite reinforcement works for
installing the means of access;
• the warranty period(s) of the means of access;
• Proper care instructions for winterization.
NOTE: A handrail may be proposed with the means of access in case of use by people with mobility
issues.
Consult manufacturer or contractor for proper care during winterization and to review maximum
weight allowed. Means of access shall not be used for any purpose besides for swim spa entry.
Stairs used for entry to the spa/swim spa must comply with section 4.6.4 of EN 17125.
A cover lifter, when applicable, should be designed to keep the cover off the ground when in use,
to avoid dirt and debris getting on the cover.
ELECTRICAL REQUIREMENTS OF SWIM SPA ACCESSORIES
Electrically operated accessories shall comply with electrical safety standards and regulations
(national and European). They must be assembled in accordance with the manufacturer's manual.
The electrical installation of any material related to the swim spa and its surroundings shall comply
with national requirements.
SAFETY DEVICES
• A safety cover or other safety protection device(s) shall be used, or all doors and windows
(where applicable) shall be secured to prevent unauthorized access to the swim spa.
• Barriers, covers, alarms, or similar safety devices are helpful aids, but they are not substitutes
for continuous and competent adult supervision.
SAFETY EQUIPMENT
• It is recommended to keep rescue equipment (e.g. a ring buoy) by the swim spa (if
appropriate).
• Keep a working phone and a list of emergency phone numbers near the swim spa.
DO NOT DIVE.
DO NOT DIVE.
100
11
In compliance with EN 17125