ResMed H5i User Manual page 11

Heated humidifier
Hide thumbs Also See for H5i:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
368148 H5i User Guide EUR1 EPN Multi.fm Page 7 Thursday, November 26, 2009 8:52 AM
WARNINGS
Read the entire manual before using these devices.
Use the device only for its intended use as described in this manual.
Do not open the H5i. There are no user serviceable parts inside. Repairs and servicing should only be performed by
an authorised ResMed service agent.
Beware of electrocution. Do not immerse the H5i, docking station or power cord in water. Always unplug the
device before cleaning and make sure it is dry before plugging it back in.
Do not use bleach, chlorine, alcohol, or aromatic-based solutions, moisturising or antibacterial soaps or scented oils
to clean the H5i or air tubing. These solutions may cause damage and reduce the life of these products.
Follow all precautions when using supplemental oxygen.
Explosion hazard – do not use in the vicinity of flammable anaesthetics.
Only use the ResMed 90W power supply units.
Make sure the power cord and plug are in good condition and the equipment is not damaged.
Keep the power cord away from hot surfaces.
Do not drop or insert any object into any tubing or opening.
Do not leave long lengths of air tubing around the top of your bed. It could twist around your head or neck while you
are sleeping.
Advice contained in this manual should not supersede instructions given by the prescribing physician.
The H5i is designed only for use with specific ResMed devices. Do not use the H5i with any other CPAP device.
Do not operate the H5i if it is not working properly or if any part of the CPAP device or H5i has been dropped or
damaged.
The H5i should only be used with tubing or accessories recommended by ResMed. Connection of other delivery
tubes or accessories could result in injury, or damage to the device.
Water must be prevented from entering your CPAP device.
Do not overfill the water tub as water may enter the device and air tubing.
Take care when handling your H5i as the water/water tub may be hot. Allow 10 minutes for the heater plate and any
excess water to cool.
The H5i docking station should only be connected or disconnected when the water tub is empty.
Make sure that the water tub is empty before transporting the H5i.
Do not operate the H5i on an aircraft as water may enter the CPAP device and air tubing during turbulence.
Always place the H5i on a level surface below the level of the user to prevent the mask and tubing from filling with
water.
The H5i should be used with caution for users who are unable to remove the mask for themselves.
If liquids are inadvertently spilled into or on the H5i docking station, unplug the device from the power outlet.
Disconnect the docking station from the CPAP device and allow the docking station to drain and dry before re-
using.
If damage to the air tubing results in air leaking, stop using the air tubing.
Do not wash the air tubing in a washing machine or dishwasher.
Avoid covering the ClimateLine air tubing with materials such as sheets or blankets.
The ClimateLine is designed only for use with the H5i.
ClimateLine is not compatible with supplemental oxygen.
7

Advertisement

Table of Contents
loading

Table of Contents