Safety Distance (S) - Miele DA 2550 Operating And Installation Instructions

Table of Contents

Advertisement

Installation
a The ducting can also be connected at the back.
b 222 x 89 mm flat exhaust ducting can be used as an alternative for ducting to
the rear or to the side.

Safety distance (S)

The minimum distances between the cooking surface of a cooktop (pan
support(s) for gas models) and the bottom of the rangehood are as follows,
unless a greater distance is specified by the manufacturer of your cooking
appliance. See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output
than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater
than 45.4 MJ/h, but with a maximum of 77.8 MJ/h,
with no burner having a greater output than
17.3 MJ/h.
Multi-burner gas cooktop with total output greater
than 77.8 MJ/h, with a single burner having a
greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output
of 21.6 MJ/h.
Single burner gas cooktop with an output greater
than 21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater
than 29.2 MJ/h.
36
Minimum distance S
600 mm (AU, NZ)
450 mm (HK, MY, SG, TH)
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Da 2570Da 2510Da 2550 extDa 2570 ext

Table of Contents