German Light Products X4 atom free connect Operating Instructions Manual page 16

Table of Contents

Advertisement

Operation
Channel Function
GLP X4 "Atom" RGBW Free Connect - Compressed mode
Channel Function
1
Master
Intensity
2
Special /
Control (All
fixtures)
3
Fixture 1
Shutter
4
Red
5
Green
page 16/24
Description
Strobe with b/o pause
Strobe - Slow to Fast
Shutter Open
Description
Master fixture intensity
No Function
No Function
No Function
Change PWM
Frequency (hold value
for more than 1 second)
All control (hold value
for more than 0.5
seconds)
Reset all fixtures (hold
value for more than 0.5
seconds)
Shutter Closed
Random strobe - Slow
to Fast
Fade on, Snap off,
Random - Slow to Fast
Snap on, Fade off,
Random - Slow to Fast
Fade on, Fade off,
Random - Slow to Fast
Strobe with b/o pause
Strobe - Slow to Fast
Shutter Open
Red Intensity
Green Intemsity
Operating Instructions X4 atom free connect
%-Range
DMX
63 - 77%
144...199
78 - 94%
200...239
95 - 100%
239...255
%-Range
DMX
0 - 100%
0...255
0 - 19.5%
0...50
20 - 25%
51...64
25.5 - 38.5%
65...99
39 - 78.5%
100...200
79 - 97%
201...247
97.5 - 100%
248...255
0 - 5.5%
0...15
6 - 18.5%
16...47
19 - 31%
48...79
32 - 43%
80...111
44 - 56%
112...143
63 - 77%
144...199
78 - 94%
200...239
95 - 100%
239...255
0 - 100%
0...255
0 - 100%
0...255
Comments