  • Page 1 Operating Instructions X4 atom free connect Version: 1.2 (2018-10-12) - en-us Support@germanlightproducts.com www.germanlightproducts.com...
  • Page 2: Table Of Contents

    7.5.5 Self test program......................18 7.5.6 Live time........................18 7.5.7 Set DMX mode......................19 7.5.8 Reset..........................19 Switch off device.......................... 19 Cleaning and maintenance........................20 Technical data.............................21 10 Recycling/disposal/environmental protection................... 22 11 Contact................................ 23 page 2/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 3: Format Conventions

    One or more bolded words indicate a term that can be found exactly the same on the product. One or more italicized words indicates an index entry or an important technical term. 1. Instructions are numbered. ✓ As are results or outcomes of these actions. 2018-10-12 Operating Instructions X4 atom free connect page 3/24...
  • Page 4: Safety

    The manufacturer is not liable for damage caused by improper use of the device. page 4/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 5: Transport And Storage

    Only store equipment in dry areas. Use the supplied or appropriate packaging material for storage and transport. To lift the device, grasp the casing with both hands. 2018-10-12 Operating Instructions X4 atom free connect page 5/24...
  • Page 6: Scope Of Delivery

    Advice Check the scope of delivery for completeness after unpacking. Check device for visible damage. Number/component Description 1 x X4 atom free connect 1 x Power cable To charge the battery 1 x Operating instructions Advice Order optional accessories directly from your specialist retailer. List to be found online at www.germanlightproducts.com.
  • Page 7: Description Of Devices

    Description of devices 5 Description of devices Overall view Image 1: Description - X4 atom free connect 1 Thumb screw 5 Antenna 2 Fixing rails 6 On/off latching switch 3 XLR cable 7 2 x safety eyelet 4 XLR connection...
  • Page 8: Assembly And Connection

    Assemble the X4 atom 1. If the X4 atom yokes are attached, then remove the yokes. 2. Push the X4 atom with the side brackets into the fixing rails of the X4 atom free connect until the release buttons click into place.
  • Page 9: Set Up Device

    Half coupler M10 threaded screws, max. 11 mm long 1. Screw a half coupler with M10 threaded screws on the underside of the X4 atom free connect in one of the M10 threaded connections. 2. Attach the half coupler to a suitable scaffold with the X4 atom free connect.
  • Page 10 Assembly and connection 1. Screw a half coupler with M10 threaded screws on the underside of the X4 atom free connect into the center M10 threaded connection. 2. Attach the half coupler to a suitable scaffold with the X4 atom free connect.
  • Page 11: Operation

    Fully charged, the battery lasts approximately 8 hours depending on usage conditions. 1. Open the cover from the power input on the bottom of the X4 atom free connect. 2. Plug the power cable into the bottom of the X4 atom free connect.
  • Page 12: Control Device

    3 ENTER: Open menu item or confirm setting Use DMX control Conditions There is a radio connection between X4 atom free connect and the DMX transmitter ▶ Control the X4 atom free connect with a DMX control. 7.5 Menu structure The menu structure consists of up to 5 menu levels.
  • Page 13 40...47 Turquoise 19 - 21.5% 48...55 Cyan 22 - 24.5% 56...63 Blue 25 - 27.5% 64...71 Lavender 28 - 30.5% 72...79 Mauve 31 - 34.5% 80...87 Magenta 35 - 37.5% 88...95 2018-10-12 Operating Instructions X4 atom free connect page 13/24...
  • Page 14 PWM frequency for more than 1 second) from 582 to 618 Hz All control (hold value 79 - 97% 201...247 Copy 1 channel to all for more than 0.5 channel seconds) page 14/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 15 Random - Slow to Fast Snap on, Fade off, 32 - 43% 80...111 Random - Slow to Fast Fade on, Fade off, 44 - 56% 112...143 Random - Slow to Fast 2018-10-12 Operating Instructions X4 atom free connect page 15/24...
  • Page 16 63 - 77% 144...199 Strobe - Slow to Fast 78 - 94% 200...239 Shutter Open 95 - 100% 239...255 Red Intensity 0 - 100% 0...255 Green Green Intemsity 0 - 100% 0...255 page 16/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 17: Special

    White adjust red (-99)-99 White adjust green (-99)-99 White adjust blue (-99)-99 White adjust white (-99)-99 Offset adjust red (-99)-99 Offset adjust green (-99)-99 Offset adjust blue (-99)-99 Offset adjust white (-99)-99 2018-10-12 Operating Instructions X4 atom free connect page 17/24...
  • Page 18: Self Test Program

    0-255 Color wheel 0-255 7.5.5 Self test program Level 2 Level 3 Level 4 Level 5 ON/OFF 7.5.6 Live time Level 2 Level 3 Level 4 Level 5 0 - 99999 page 18/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 19: Set Dmx Mode

    DMX compressed mode 7.5.8 Reset Level 2 Level 3 Level 4 Level 5 ON/OFF 7.6 Switch off device ▶ Disconnect the device from the power supply. ✓ The device is switched off. 2018-10-12 Operating Instructions X4 atom free connect page 19/24...
  • Page 20: Cleaning And Maintenance

    Cleaning and maintenance 8 Cleaning and maintenance The X4 atom free connect is a low-maintenance device. Depending on the operating environment, surfaces must nevertheless be cleaned at regular intervals. Warning Danger of electrical shock. Electric cables can cause serious injury if they come into contact with cleaning agents.
  • Page 21: Technical Data

    2.8 dBi @ 2400 – 2500 MHz Polarization Vertical Operating conditions Operating temperature 0 – 45°C 32 – 113°F Storage temperature -20 – 45°C -4 – 113°F Humidity Maximum 90%, non-condensing 2018-10-12 Operating Instructions X4 atom free connect page 21/24...
  • Page 22: Recycling/Disposal/Environmental Protection

    At the end of its service life, return the device free-of-charge to the manufacturer, point of sale or a public collection point set up for this purpose. page 22/24 Operating Instructions X4 atom free connect 2018-10-12...
  • Page 23: Contact

    To use the online support, it is required to go through a one-time registration process. Then log into the online support using your registered user account. E-mail support@germanlightproducts.com Phone +1 818 767 8899 2018-10-12 Operating Instructions X4 atom free connect page 23/24...
  • Page 24 GLP German Light Products, Inc. 1145 Arroyo Ave., Unit A San Fernando, CA 91340 Phone: +1 818 767 8899 E-mail: Support@germanlightproducts.com Website: www.germanlightproducts.com...