German Light Products X4 atom free connect Operating Instructions Manual page 14

Table of Contents

Advertisement

Operation
Channel Function
6
Fixture 1 Red
7
Fixture 1
Green
8
Fixture 1
Blue
9
Fixture 1
White
10
Fixture 1
Zoom
11
Fixture 1
CTO
GLP X4 "Atom" White Free Connect - 12 Way
Channel Function
1
Master
Intensity
2
Special /
Control (All
fixtures)
page 14/24
Description
Pink
CTC 3200K
CTC 5600K
CTC 7200K
Rainbow Effect - Stop
Rainbow Effect - Slow
to Fast
Random Colors - Slow
to Fast
Red Intensity
Green Intemsity
Blue Intensity
White Intensity
Variable, wide to narrow
(50 to 7 degrees)
No Function
Variable CTO
(10000K-2700K)
Description
Master fixture intensity
No Function
Activate Silent Mode
(hold value for more
than 1 second)
No Function
Change PWM
Frequency (hold value
for more than 1 second)
All control (hold value
for more than 0.5
seconds)
Operating Instructions X4 atom free connect
%-Range
DMX
38 - 40.5%
96...103
41 - 43.5%
104...111
44 - 46.5%
112...119
47 - 49.5%
120...127
50%
128
51 - 88%
129...223
89 - 100%
224...255
0 - 100%
0...255
0 - 100%
0...255
0 - 100%
0...255
0 - 100%
0...255
0 - 100%
0...255
0 - 3%
0...7
3 - 100%
8...255
%-Range
DMX
0 - 100%
0...255
0 - 19.5%
0...50
20 - 25%
51...64
25.5 - 38.5%
65...99
39 - 78.5%
100...200
79 - 97%
201...247
Comments
Colors determined
via RGBW channels
Comments
Primary Intensity
Channel over all
fixtures connected
Activate silent mode
on all fixtures
Variabally adjust
PWM frequency
from 582 to 618 Hz
Copy 1 channel to all
channel
2018-10-12

Advertisement

Table of Contents
loading