20A AC STAGE & TRUSS MOUNT PLUG BOARD
Neutrik 20A 240V Blue
PowerCON input connector
For the full 20A usage the
right cable & supply
source should be used
Fitting a 13A plug will
de-rate this board
LINK OUTPUT is a grey 20A
PowerCON output connector
and is directly coupled
to the Power Input Socket
not via the breaker circuit
For safety it must be remembered when using the LINK output that the
combined load of the 'Daisy Chained' units should not exceed 20A.
If the switch is in the reset position
1st check the power is connected &
POWER INPUT SIDE
LINK OUTPUT SIDE
USERS GUIDE
RED Neon Indicator
and lit - this shows there should
be AC power to the board.
Should these Not be Lit then -
none of the outputs are being
overloaded
16A Trip Switch
for the 6 UK sockets
in the event of overload
this will cut the power

Advertisement

loading

Summary of Contents for Penn Elcom PDU16-6UK

  • Page 1 PDU16-6UK USERS GUIDE 20A AC STAGE & TRUSS MOUNT PLUG BOARD Neutrik 20A 240V Blue RED Neon Indicator PowerCON input connector If the switch is in the reset position and lit - this shows there should For the full 20A usage the be AC power to the board.
  • Page 2 2 + PDU16-6UK can linked via the though link outputs to give 12 or more remote outputs with a TOTAL maximum working load of 20A PLEASE NOTE THE MAIN INPUT SOCKET OF ANY CHAIN IS RATED AT 20 AMPS M10 fixing for G Clamp...
  • Page 3 Declaration of Conformity The Manufacturer of the Products covered by this Declaration is Made in the UK by Penn Elcom 9-10 Parsons Road, Parsons Industrial Estate, Washington Tyne & Wear, NE37 1HB, UK The Directives covered by this Declaration 89/336/EEC Electromagnetic Compatibility directive, as amended...
  • Page 4 Insulation Resistance: 100 megohms. Maximum Operating Voltage: 250VAC, 50/60 Hz. These switches have the following certification approvals: UL 1077 , VDE 0642/EN60934, CCC & CE compliant. Penn Elcom Ltd excepts no responsibility or liability for any equipment connected to this unit...