Specifications - Panasonic EX-FC1 Instruction Manual

Simple wire-saving unit for leak detection sensor
Hide thumbs Also See for EX-FC1:

Advertisement

5
CONNECTION
● Make sure to connect or disconnect the snap male connector (SL-CP1)
in the power supply off condition.
● Take care that wrong wiring will damage the product.
● The terminal No. 4 of the snap male connector (SL-CP1) is not used.
Take care not to connect to the terminal No. 4 by mistake. Further, if
there are unused wires, please insulate them.
1 2 3 4
1
2
3
4
● For details of the hook-up method of the snap male connector (SL-CP1),
refer to the Instruction Manual enclosed with SL-CP1.
Connection method
1. By holding the SL-CP1 with the cable
connected, insert it into the connector
of the EX-FC1 reliably till it stops.
Disconnection method
2. By holding SL-CP1, pull it from the
EX-FC1 horizontally.
Note: Do not pull out by holding the cable, as this
can result in cable disconnection.
6
CONNECTION SETTING SWITCH
The connection setting should be carried out in the power supply off condi-
tion after removing any electrostatic charge which may be present on your
body.
● Operation matrix for each indicator
Connection
State of the
state of the
connection
Operation
leak detec-
setting
tion sensor
switch
Connected
ON
Normal
Unconnected
OFF
Connected
OFF
Error
Unconnected
ON
● For the channel that the unit sensor is connected to and the connection
setting switch is set to "ON" side, the error indicator (red) lights up for a
moment when the power is turned on. This is not a malfunction for the
unit because it is caused by characteristic of the sensor.
● Make sure to set the connection setting switch with the connector No. to
which the leak detection sensor is connected, to "ON" side.
● In case both the normal indicator (green) and the error indicator (red)
light up, the connection setting switch with the connector No. to which
the leak detection sensor is connected, is not set to "ON" side. Set the
connection setting switch with the connector No. to which the leak detec-
tion sensor is connected, to "ON" side.
● In case the error indicator (red) lights up, the leak detection sensor de-
tects leak or the connection setting switch is set to "ON" side without
connecting the leak detection sensor. If the connection setting switch is
set to "ON" side without connecting the leak detection sensor, set the
connection setting switch to "OFF" side.
● If the leak detection sensor detects leak or the connection setting switch
is set to "OFF" side in the state that the leak detection sensor is improp-
erly mounted to the mounting bracket, the sensor judges as the output is
ON. Be careful when setting.
NOT
These are not used.
USED
7
6
5
"ON" side
4
"ON" side
3
"ON" side
2
1
0
"ON" side
ON
Connection setting switch setting example
In case the input of 0, 3, 4 and 5 are set
to effective.
Content
1
+V
2
0V
3
IN
4
No connected
EX-FC1
SL-CP1 (Accessory)
Cable of the leak
detection sensor
Leak
Normal
Error
detected
indicator
indicator
condition
(Green)
(Red)
Not leaked
Lights up
Turns off
Leaked
Turns off
Lights up
-
Turns off
Turns off
Not leaked
Lights up
Lights up
-
Turns off
Lights up
Connector No.
7

SPECIFICATIONS

Designation
Item
Model No.
Applicable connector
Supply voltage
Current consumption
Output
Output operation
Response time
Input points
Ambient temperature
Ambient humidity
Material
Cable
Weight
Accessory
8
CAUTIONS
● This product has been developed / produced for industrial use only.
● This product is suitable for indoor use only.
● Avoid using the product in an explosive atmosphere because this prod-
uct does not have an explosive-proof protective construction.
● Make sure that the power supply is off while wiring.
● Take care that wrong wiring will damage the product.
Output
● Verify that the supply voltage variation is within the rating. Take care that
indicator
if a voltage exceeding the rated range or an AC power supply is directly
(Orange)
applied, the sensor may get damaged or burnt.
● If power is supplied from a commercial switching regulator, ensure that
Lights up
the frame ground (F.G.) terminal of the power supply is connected to an
Turns off
actual ground.
Lights up
● In case noise generating equipment (switching regulator, inverter mo-
Turns off
tor, etc.) is used in the vicinity of this product, connect the frame ground
Turns off
(F.G.) terminal of the equipment to an actual ground.
● Do not run the wires together with high-voltage lines or power lines or
put them in the same raceway. This can cause malfunction due to in-
duction.
● Do not use during the initial transient time (approx. 0.5 sec.) after the
power supply is switched on.
● Cable extension is possible up to total 10m with 0.3mm
cable. However, in order to reduce noise, make the wiring as short as
possible.
● Make sure that stress by forcible bend or pulling is not applied to the
cable joint.
● Since the output does not incorporate a short-circuit protection circuit,
make sure to use this product within the specification and take care
against wrong wiring.
● In case a surge is generated in the used power supply, connect a surge
absorber to the supply and absorb the surge.
● Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product or
the power supply may get damaged.
● Avoid dust, dirt, and steam.
● Take care that the product does not come in contact with oil, grease or
organic solvents, such as, thinner, etc., strong acid or alkaline.
● This sensor is suitable for indoor use only.
INTENDED PRODUCTS FOR CE MARKING
9
● The models listed under "
CE Marking.
As for all other models, please contact our office.
● Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN
Simple wire-saving unit for leak detection sensor
EX-FC1
SL-CP1
12 to 24V DC± 10 % Ripple P-P 10% or less
50mA or less (for one unit)
135mA or less (including the sensor input current when all
outputs are ON)
Relay contact 1a
• Switching capacity: 30V 1A DC (resistant load)
• Min. applied load: 10mV 10μA DC
• Electrical lifetime: 100,000 times or more
(rated load, switching frequency 20 times/min.)
• Mechanical lifetime: 50,000,000 times or more
(switching frequency 180 times/min.)
The output relay is ON when the input signal from the sensor is ON.
5ms or less (excluding the response time of the sensor)
8 points
-10 to +60ºC (No dew condensation or icing allowed)
Storage: -20 to +70ºC
35 to 85% RH, Storage: 35 to 85% RH
Enclosure: ABS, Terminal part: PBT
2
0.2mm
4-core cabtyre cable, 2m long
Approx. 85g
SL-CP1 (Snap male connector): 8 pcs.
MS-SL-2 (Unit mounting base): 1 pc.
SPECIFICATIONS" come with
© Panasonic Industrial Devices SUNX Co., Ltd. 2015