Knx S-Mode Parameter Description; Room Temperature Sensor; Room Temperature Control - Siemens QMX3.P37 Technical Principles

Wall-mounted sensors and room operator units for knx s-mode and knx lte-mode, infrastructure & cities
Hide thumbs Also See for QMX3.P37:
Table of Contents

Advertisement

Designation
Communication objects available in ETS
when function is enabled
Room temp.: Sensor correction
Room temp.: Send following change by
Room temp.: Send cyclically after
Activate room temperature control
Heating type
Cooling type
Parameters heating / cooling type allow for adapting the
controller to the type of heating / cooling. In addition, the
controller features two control algorithms: one for continuous
mode (0..100%) and one for PWM mode (On/Off). The mode
is selected via parameter "Control value type". The control
value type is identical for all operating modes. In continuous
mode, the associated PWM output is "On" at continuous
control value ≠ 0.
In PWM mode, cycle time and pulse width are adapted to the
type of heating / cooling, the setpoint, and the measured room
temperature. The min. cycle time is 12 minutes, the min. pulse
width is 4 minutes. The continuous control value issues 0% or
100% in this operating mode.
Default heating setpoint
Default cooling setpoint
Control value type
Send cyclically after
Protection heating setpoint
Economy heating setpoint
Comfort heating setpoint
Comfort cooling setpoint
Economy cooling setpoint
Protection cooling setpoint
Comfort extension time
Number of window status inputs
Siemens
Building Technologies
6.4

KNX S-Mode Parameter description

Factory settings are boldfaced / in brackets
6.4.1

Room temperature sensor

6.4.2

Room temperature control

Wall-mounted sensors and room operator units for KNX S-Mode and KNX LTE-Mode CM2N1602en_01
GAMMA building management system
Values
Range
(Default)
-5...+5
in0.1 steps
(0K))
0.1...2.5 (0.1)
1...60 (2 min)
yes; no
Radiator heating slow
(Radiator heating fast)
Floor heating slow
Floor heating fast
(Chilled ceiling)
Floor cooling
5...40 (21.0)
5...40 (24.0)
(PWM)
Continuous 0...100%
Do not send cyclically
1;2;3...30;45;60
5...40 (12.0)
5...40 (15.0)
5...40 (21.0)
5...40 (24.0)
5...40 (28.0)
5...40 (35.0)
5...120 (30)
0...4
Type
X
X
X
X
K
X
X
X
X
K
X
X
X
X
min
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
°C
°C
X
X
X
X
X
X
X
X
min
X
X
X
X
X
X
X
X
°C
X
X
X
X
°C
X
X
X
X
°C
X
X
X
X
°C
X
X
X
X
°C
X
X
X
X
°C
X
X
X
X
min
X
X
X
X
2013-07-04
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
31 / 40

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qmx3.p34Qmx3.p02Qmx3.p74Qmx3.p30Qmx3.p70

Table of Contents