Label Formatting Mode
Wx / W1x:
RFID
abbbcdeeeffffggggjj....j
Field
a
Operation to perform (Read/Write/Write Verify)
bbb
Wnx, RFID Hexadecimal Operation. No n is an implied 1.
c
Not Used
d
Not Used
eee
xyy, Lock after write
x = 0 - Use printer setup to determine if lock is performed after write.
x = 1 – Perform lock after write.
yy = Lock Code where yy is a 2 character hex value (UHF only).
ffff
Starting Block # (HF only), Valid Entries 0000 – 9998
gggg
Not Used
jj...j
Valid Hexadecimal character string followed by a termination
character.
Note 1: Read function not currently implemented.
Example:
<STX>L
D11<CR>
2W1x0000000010000446174616D61782077726974657320524649442062657374<CR>
E
The example above:
Field 1
"2W1x
0000000010000446174616D61782077726974657320524649442062657374
the printer encodes the RFID chip starting at block 001 with "Datamax writes RFID best".
Valid Inputs
Meaning
1
1-Read
,
2- Write,
3-Write/Verify
RFID
Starting block #
to write
Write Data
<CR>",