Recheck if the outer glass of the GGA is touching the heat rail gasket on both ends.
14.
Check for any excessive play by lightly pulling the GGA outwards. The play (rattle / movement) should be
15.
negligible in the system when the GGA is held in position by the latches.
If there is excessive play, the GGA catches on the bottom of the GGA should be adjusted forward to
16.
reduce the play to a minimal amount. This is to ensure GGA can still be secured and released smoothly
without excessive force (Fig. 20).
note:
The GGA should slide smoothly back and latch with a 'click'. Front to back play should be negligible. The GGA
should unlatch smoothly without the need for excessive force. Continue to adjust the GGA catches and/or
latches until the GGA can be moved correctly. Tighten all screws securely but do not overtighten.
Remove GGA (see, "to remove GGA" section) and safely store the GGA after preliminary adjustment.
17.
Ensure GGA is placed on a non-abrasive material to avoid scratches. It is recommended to store the GGA
in the original packaging taking care to ensure glass surfaces are protected from scratches.
Re-install GGA after the appliance finishing then re-check alignment.
18.
Secure GGA by tightening the GGA slider bracket screws on both ends securely.
19.
For see-thru models, repeat instructions for second GGA to be installed on the fixed side.