iRC6800-010
Note:
As opposed to the use of a CCD, the use of a reflection type sensor will not permit detection of the following: for
AB-configuration, absence of paper, B6, A5; for Inch-configuration, absence of paper, STMT, STMT-R.
Installation Procedure
When installing the Vertical Size Sensor Kit (Inch; FM2-0647), be sure to upgrade the reader controller software
to version 9.02 or later (iR C6800 Series).
1.Check the contents of the kit.
[1]
[2]
[4]
[5]
[3]
F-1
[1] Vertical size sensor unit.......................1 pc.
[2] Horizontal size sensor..........................1 pc.
[3] Clamp ..........................................5 pc.
[4] Edge saddle.....................................1 pc.
[5] RS tightening screw (M4x8)..................... 1 pc.