1.1 Points to Note About Installation
1.1.1 Points to Note About Installation
Take note of the following to avoid damaging the PCBs by static charges:
1. Put on a grounded wrist strap before starting the work. If no grounding terminal is found, use the frame of the main
body.
2. Keep each PCB in an anti-static bag until immediately before it is used.
3. When you handle a PCB, be sure to hold the frame of the PCB (i.e., base material area) without touching terminals.
4. If you must place a PCB temporarily, be sure that the area is treated against static charges (e.g., anti-static mat).
Otherwise, place it on or in an anti-static bag. Do not place it on a metal plate.
5. Be sure not to leave insulators which are subject to being charged in the work area.