4 | Prepare Data Base
5 Volt
3.01 kOhm pullup
PULLUP_"function"
MS6 sw.pullup:
CWPULLUP_"pin"
MS6 input
PIN_IN_U"function"
40 / 76
Principle structure of analogue signal conversion
input-voltage:
u"function"
Pressure measurements
The system offers a lot of different pressure channels, please see function description in-
put signal processing for details. For gradient and offset information contact sensor man-
ufacturer.
Example: Ambient Pressure
PAMB_OFF, PAMB_GRD
UPAMB_MIN, UPAMB_MAX
PAMB_DEF
FCPAMB
All other variables are named by the same rule, replace "pamb" by e.g. "poil" to apply data
for the oil pressure sensor.
Temperature measurements
The system offers a lot of different temperature channels, please see function description
input signal processing for details.
Example: Intake Air Temperature
UTINT_MIN, UTINT_MAX
TINT_CONV
Engine_Control_Unit_MS_6.x_Manual
sensor offset
sensor gradient
„function" _OFF
„function" _GRD
_
/
2 point- and offset adjustment for
determination of sensor values
CW"function"CAL: choice of adjustment
„function"CAL/Pos1/Pos2: value of adj.
sensor mapping line (R)
function_CONV
Sensor offset and gradient
Minimum and maximum accepted sensor
voltage. When violated, an error is set
(E_pamb = 1).
Default value if an error occurred.
Filter constant. For ambient pressure use 1
second, for other pressures choose appro-
priate values, ~ 100 to 200 milliseconds
Minimum and maximum accepted sensor
voltage. When violated, an error is set
(E_tint = 1).
Sensor characteristic. Consult the sensor
manufacturer.
phys. converted
measure channel
phys. converted
measure channel
phys. converted
measure channel
Bosch Motorsport