9 | Error Memory

70 / 76
9 Error Memory

9.1 Error Memory representing in RaceCon

– Bosch Motorsport devices feature an error memory. Information on detected errors
can be visualized via RaceCon (online measurement) or can be transmitted via tele-
metry.
– Select any configured device of the system and inspect the "error info" folder.
– Adapt the messages to the configured hardware. In general, properties of the error
memory and properties of an individual error need to be distinguished.
– The memory is situated inside the device and non-volatile. As a consequence, an error
which has occurred and has not been cleared by the user will remain in the error
memory even after a power cycle. The error state will then reflect if the error is still
active or not.
– An error is deleted from the list when
– the user actively clears the error memory,
– the user updates the firmware.
– Clearing the error memory
– in the top right corner of the error monitor,
– alternatively at the bottom of the menu bar,
– alternatively reset the error monitor in the measurement folder >CLRERRMON<
= TRUE.

9.2 Writing an Error

For the functional part of the MS 6 system (MS 6-ECU) the error bits are related to the
function and have to be distinguished if the function is activated. If an error is detected,
the information may be shown as part of the error monitor in RaceCon, as display inform-
ation and as measure channel. To support driver visibility, an activated error may activate
also an output to enable the MIL-light (B_mildiag will be enabled).