iring diagram
Fig. D-9
Field lead wires have to be tightened
in the Motor housing so as not to
touch Armature.
Field Lead wire (white)
Field Lead wire (purple)
Do not route Field lead wires
(white and purple) between
Armature and Baffle plate.
Pass Lead wires from Motor housing
through the notch of Handle.
Wiring in Motor Housing and Handle for
where Radio Interference suppression is not required.
Insulated terminal
Field Lead wires
* (orange)
* (black)
* (yellow)
Pass Lead wires through ribs as illustrated.
Do not put their Lead wires on the ribs.
220 - 240V
Case of Power
supply circuit
Connection of Receptacles
Receptacles have to be connected
so that their wire connecting
portions face the bottom of Handle.
Bottom of Handle
P 32/ 35
area
Do not put Lead wires on
these ribs.
Controller
ribs for Laser
switch unit
Switch for protection
of brake coil
Receptacles
Wire connecting portion
rib