Panasonic DP-100 Series Instruction Manual page 3

High-performance digital display pressure sensor
Hide thumbs Also See for DP-100 Series:

Advertisement

9
PRO MODE
The mode will change to RUN mode when the mode selection key is held down
during this setting process. However, changed items before holding down the mode
selection key have been set.
RUN mode
When "No. display" or "Custom display" is set in "Sub display selection."
Press for
<Sub-display selection>
4 seconds
When "
" is set
<PRO mode>
When "
" is set
Set pressure
range is displayed
on sub display.
<Sub-display selection>
Standard
Display OFF
Unit display
<Display speed selection>
250ms
500ms
1,000ms
+\VWHUHVLV ¿[HG YDOXH VHOHFWLRQ!  OHYHO $SSUR[  GLJLW :KHQ 3D XQLW LV VHOHFWHG
Standard type only
<Displayed color relation selection>
Relating with
Relating with
comparative
comparative
output 1
output 2
<Eco mode setting>
OFF
Standard
Max.
<Setting check code>
Automatic
<Setting copy mode>
Copy sending
Copy sending
Copy sending
OFF
ON
ON-L
<Reset setting>
RUN mode
Setting item
Factory setting
Changes the indication of the sub-display.
"
" : Displays nothing.
"
" : Presently selected pressure unit is displayed.
Sub-display selection
"
" : Desired No. can be shown.
"
" : Desired numbers, alphabets (some of them cannot be displayed)
Display speed
Changes the speed of the displayed pressure value on the main display.
selection
+\VWHUHVLV ¿[HG
Sets hysteresis of the EASY mode and the window comparator mode.
value selection
(8 steps)
Displayed color rela-
The setting contents set at the displayed color setting in Menu setting mode
tion selection
can be related with either comparative output 1 or comparative output 2.
(Standard type only)
Current consumption can be lowered.
"
" : Normal operation (ECO mode is off.)
"
" : If any key operation is not carried out for approx. 5 sec. in RUN
Eco mode setting
"
" : If any key operation is not carried out for approx. 5 sec. in RUN
Press any key to temporarily show the normal indication.
Setting check code
Current setting contents can be checked. For codes. refer to "Code table".
The setting of the master side sensor can be copied to the slave side sensors.
For details, refer to "
Setting copy mode
"
" : The setting contents are copied.
"
" : The setting contents are copied, and the slave side sensor goes
Returns to default settings (factory settings).
Reset setting
By pressing dowun mode key when "
(factory settings).
Change the displayed details with
RUN mode
Custom
No. display
display
Max.
Min.
Copy ready
state
Description
and signs can be shown.
mode, the display becomes dark.
mode, the display is turned off.
10
SETTING COPY FUNCTION."
into key-lock state.
" mode, becomes default settings
Code table
Main display (1st digit form left)
1st digit
Standard type
Comparative
Comparative
N.O. / N.C.
output 1
output 2
selection
output mode
output mode
N.O.
OFF
EASY
N.C.
EASY
N.O.
Hysteresis
N.C.
Hysteresis
N.O.
Window
comparator
N.C.
Window
comparator
-
-
-
-
-
Sub-display (5th digit from left)
5th digit
6th digit
Response time
Unit selection
2.5ms
MPa
5ms
kPa
10ms
kgf/cm
25ms
bar
50ms
psi
100ms
mmHg
250ms
inchHg
500ms
-
1,000ms
-
5,000ms
-
10
SETTING COPY FUNCTION
This can copy the settings of the master side sensor to the slave side sensor.
Be sure to use the setting copy function between the identical models.
This function cannot be used between different models.
Only one sensor can be connected on slave side with a master side sensor for the
setting copy function.
Setting procedure
1. Set the setting copy function of the master side sensor to "Copy sending ON" or
"Copy sending ON-L", and then press the mode selection key so that the sen-
sor is in copy ready state. For details, refer to <Setting copy mode> in "
MODE".
2. Turn OFF the master side sensor.
3. Connect the master side sensor with the slave side sensor as shown below.
Color code of cable
with connector
Master side sensor
(Brown) +V
(Blue) 0V
(Black) Comparative output 1
(White) Comparative output 2 (Note 1)
Notes: 1) For the high-function type, external input.
4. Turn ON the master side sensor and the slave side sensor at the same time.
(Note 2) (Note 3)
5. Set contents (16-bit coded) are shown in orange on the main display of the master
side sensor and the copying starts.
6. The same code explained above is shown in green on the main display of the slave
side sensor, and
is shown on the sub-display (When copying is complete.)
7. Turn OFF the power of the master side sensor and the slave side sensor and dis-
connect the wire.
* If copying the setting to another sensor repeatedly, follow steps 3 to 7.
Notes: 2) Take care that if the power is not turned on at the same time, the setting contents may not be copied.
3) Note that when the power is on, pulse output is output to comparative output 1.
To cancel the setting copy mode of master side sensor
1. Whilst the slave side sensor is disconnected, turn on the power of the master side
sensor.
2. Press the mode selection key for approx. 2 seconds.
2nd digit
3rd digit
High-function type
Analogue
Displayed
N.O. / N.C.
voltage / cur-
Threshold
color of the
selection
rent output /
display
main display
external input
Analogue
OFF
P-1, Lo-1
voltage output
Red when ON
N.O.
Auto reference
Hi-1
Remote zero-
N.C.
P-2, Lo-2
adjustment
Green when ON
Analogue
N.O.
Hi-2
current output
N.C.
-
ADJ.
Always red
N.O.
-
-
N.C.
-
-
Always green
-
-
-
7th digit
Display speed
250ms
500ms
2
1,000ms
-
-
-
-
-
-
-
Power supply
Slave side sensor
+V (Brown)
0V (Blue)
Comparative output 1 (Black)
Comparative output 2 (Note 1) (White)
4th digit
Standard type
Displayed
color relation
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
8th digit
Eco mode
OFF
Std
Full
-
-
-
-
-
-
-
PRO
9