Table 5-2 Operating and storage temperatures and humidity for the ME936 module
Specification
Normal working temperatures
Extended temperatures
Ambient temperature for storage
5.4 Power Supply Features
5.4.1 Input Power Supply
Table 5-3 lists the requirements for input power of the ME936 module.
Table 5-3 Requirements for input power for the ME936 module
Parameter
3.3V
Figure 5-1 Power Supply During Burst Emission
Issue 03 (2017-12-11)
[1]: When the ME936 module works at this temperature, all its RF indexes comply with the
3GPP TS 45.005 specifications.
[2]: When the ME936 module works at this temperature, NOT all its RF indexes comply with
the 3GPP TS 45.005 specifications.
Min.
3.135
The minimum value of the power supply must be guaranteed during the burst (with 2.5 A Peak
in GPRS or EGPRS mode).
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Min.
–10
[1]
–20
[2]
–40
Typ.
3.3
Electrical and Reliability Features
Max.
+55
+70
+85
Max.
Ripple
4.4
0.05
Unit
° C
° C
° C
Unit
V