Item
Type / Charge
GWP
Refrigerant
No need to recharge
Recharge
Liquid
Pipe
Gas
Connecting method
Drop between IU & OU
Piping
Piping length between IU & OU
Total liquid piping length
Drop between indoor units
Max.Drop between IU &OU
Max.Drop between indoor units
Max.Piping length between IU & OU
Max Cable length between IU & OU
Max.Total length
Cooling
Working temperature
Heating
Pto: 47W
Psb: 16W
A (Cap/EER)
9511W/2.8
B (Cap/EER)
7170W/5.12
Cooling
C (Cap/EER)
4095W/9.04
D (Cap/EER)
4026W/11.98
Indoor temperature:32°C/23°C
Max. cooling condition
Outdoor temperature:46°C/-°C
kWh/annum
1. The above performance data are from the combination of 5U105S2SS2FA+2*AS25S2SF2FA+1*AS35S2SF2FA+1*AS50S2SF2FA.
2. Large drop and long piping installation will obviously reduce the total capacity.
Model
kg
m
g/m
mm
mm
——
m
m
m
m
m
m
m
m
m
°C
°C
Heating
Max. heating condition
537
kWh/annum-average
116
5U105S2SS2FA
R32 / 2.4
675
40
20
5* Φ6.35
3* Φ9.52+2*Φ12.7
Flared
≤7.5
≤10
≤40
≤1
15
7.5
25
30
80
-10~46
-15~24
Pck: 0W
A (Cap/COP)
6457W/2.63
B (Cap/COP)
4691W/3.74
C (Cap/COP)
3108W/5.26
D (Cap/COP)
2835W/6.52
Indoor temperature:27°C/-°C
Outdoor temperature:24°C/18°C
2889
Poff: 0W
Tol (Cap/COP)
7046W/2.56
Tb (Cap/COP)
6457W/2.63
Cd (cooling)
0.25
Cd (heating)
0.25
kWh/annum-
1279
warm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents