Feature - Haier 1U71S2SG1FA Service Manual

R32 super match ii multi split
Hide thumbs Also See for 1U71S2SG1FA:
Table of Contents

Advertisement

1. Feature

Item
Power cable
Communication cable/Connecting cable
Power source
Start current
Unit model (color)
Compressor
Fan
Heat
Outdoor
exchanger
unit
Dimension
Drainage pipe (Material , I.D./O.D.)
Refrigerant control method
Defrosting
Volume of accumulator
Sound power noise level
Sound pressure noise level (H-M-L)
Type of four way valve
Material of reduce noise
Crankcase heater power
Weight (Net / Shipping)
Refrigerant
Piping
Pipe
Connecting method
Between
I.D &O.D
Cooling(Min-Max)
Working
temp.
Heating(Min-Max)
Norminal condition: indoor temperature (cooling): 27°C DB/19°C WB, indoor temperature (heating): 20°C DB
Outdoor temperature(cooling): 35°C DB/24°C WB, outdoor temperature(heating): 7°C DB/6°C WB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity
meter. It is a sound pressure noise level.
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Type × Number
Speed
Fan motor output/Input
Power pow
Air-flow(H-M-L)
Type / Diameter
Row / Fin pitch
External(L*W*H)
Package(L*W*H)
(H-M-L)
Type / Charge
Maximum pipe length without
recharge refrigerant
GWP
Recharge quantity
Liquid
Gas
MAX.Drop
MAX.Piping length
Model
N, V, Hz
1PH,220-230VAC,50/60HZ
A
3
SNB130FGYM2/SNB130FGYMC-L1(MGC)
r/min
950/830/750/700/500/420/300
W
m³/h
mm
mm×mm×mm
mm×mm×mm
mm
mm/mm
1.8mmEEV+Φ3.0*Φ1.8*200mmCapillary
L
dB(A)
dB(A)
W
kg / kg
g
m
g/m
mm
mm
m
m
°C
°C
106
1U71S2SG1FA
H05RN-F 4G 6.0mm2
H05RN-F 4G 2.5mm2
3
1U71S2SG1FA(WHITE)
FV50S
PVE
500CC
Rotary
axial×1
97/70
3000
TP2M/Φ7.9
2/1.65
860/308/730
995x420x815
/
Auto
None
70
57
Shf-4-10a
Felt
/
49/52
R32/1600
5
2088
45
9.52
15.88
Flared
15
25
-10~46
-15~24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents