Configuration - Delta CS2 Technical Information

Scanning/lighting system
Table of Contents

Advertisement

Configuration

2
4
8
Internal Trigger
External Trigger
High Ratio
Low Ratio
LED's
Configuration
Jumpers
LED's
Delta Computer Systems, Inc., 11719 NE 95th Street, Vancouver, Washington 98682-2444 (360) 254-8688
Default Jumper Configuration
2
4
8
Internal Trigger
External Trigger
High Ratio
Low Ratio
Bar Graph
TB2
TB1
Status
Indicators
email@deltacompsys.com http://www.deltacompsys.com
CS2 Color Scanner
Sense Low/High Ratio
The Sense Limit is jumper configurable to respond to
either Sense/Base ratios that are lower than normal (Low)
or Sense/Base ratios that are higher than normal (High).
Example applications where the Dark setting (default) is
used including detecting green areas on carrots, knots on
wood and burnt cookies, while the High setting would be
used to detect white ends on asparagus, some paint
applications, etc.
External and Internal Triggers
When using the Internal trigger (default), every 500
microseconds the CS2 automatically takes new Sense and
Base color readings, calculates averages and Sense/Base
ratio and updates the outputs and indicators.
If an external trigger is desired, move the jumper from the
internal trigger position to the external trigger position and
wire the output of the RPG (or other trigger source) to the
Trig In terminals located on TB1.