Delta CS2 Technical Information page 13

Scanning/lighting system
Table of Contents

Advertisement

CS2 Color Scanner
spacing or controlling the scans. If CS2s are mounted such
that the light from one does not extend into the other's
viewing area, then they will not interfere with each other.
In multiple unit applications, it is often advantageous to
have the units next to each other so that they take up as little
space as possible. The light from each unit will extend into
the adjoining unit's viewing area. In this case, interference
can be avoided by using the External Trigger mode and
triggering adjacent units at different times. A separation of
50 microseconds is sufficient. In applications which use a
quadrature output rotary pulse generator, this can be done by
connecting ajacent units to the other output phase, i.e.
scanners 1, 3, 5, etc. to phase A and scanners 2, 4, 6, etc. to
phase B.
If large numbers of units are required, you may want to
consider a custom scanner. Multiple units can be packaged
into a single enclosure, resulting in a cleaner package. Units
can also be packaged around a tube, etc. Contact Delta for
details.
Delta Computer Systems, Inc., 11719 NE 95th Street, Vancouver, Washington 98682-2444 (360) 254-8688
13
email@deltacompsys.com http://www.deltacompsys.com