Using The Displays; Bar Graph Display; Status Indicators; Inputs And Outputs - Delta CS2 Technical Information

Scanning/lighting system
Table of Contents

Advertisement

Using the Displays

LED's
LED's

Bar Graph Display

In order to make adjustment easy, the CS2 contains its own
voltmeter with a bar graph display which is visible through
the top. This display uses a "moving dot" technique where
the segment position represents the amplitude of the
reflected light.
Output Bar Graph Display
Green
Yellow
Bright bar indicates Sense Color
The lowest voltage segments are yellow, the center green,
and the highest are red. Usually, once the Gains are
adjusted, the background intensity will be no higher than the
yellow segments and normal objects will be in the green
range. The 10th (red) segment indicates an overrange
condition; at this point the readings are invalid. The Gains
need to be set such that the highest intensity is not higher
than the 9th segment.
Both the Base color and the Sense color are simultaneously
displayed using a different intensity for each color. The
brighter LED represents the Sense color.

Status Indicators

Four indicators provide status of the digital inputs and
outputs. Indicators are lit when the condition they represent
is true (Output NPN transistor ON).
Data Ready
Base Limit
Sense Limit
Delta Computer Systems, Inc., 11719 NE 95th Street, Vancouver, Washington 98682-2444 (360) 254-8688
Bar Graph
TB2
TB1
Status
Indicators
Trig In
Less intense bar indicates Base Color
Red
Trig In
email@deltacompsys.com http://www.deltacompsys.com
CS2 Color Scanner

Inputs and Outputs

The CS2 provides two analog and three digital outputs and
two analog inputs. The digital outputs are: Data Ready,
Base Limit and Sense Limit. All three are optically isolated
uncommitted NPN open-collector outputs.
The two analog outputs provide voltages proportional to the
real time Base color and Sense color. Updated every scan
cycle, the outputs range from 0-10V and will drive high
impedance inputs
(2 kohms or higher). These outputs are
not temperature compensated and must be used with the
appropriate software algorithms.

Scan Cycle

Internal
Trigger
OR
External
RPG Phase
(NPN output ON)
Trigger
Input
Measure
S
Sense
Measure
B
Base
Data
Busy
Ready
(NPN output ON)
Output
Limit &
Analog
Outputs
Trigger Delay Time
(Determines Scan
Cycle Time when
using internal
Data
trigger)
Ready
(default) 500us
110us
435us
110us
380us
110us
330us
110us
275us
110us
220us
110us
164us
110us
110us
55us
*50us
25us
*Special order, must
be set by factory
Note 1. When using an external trigger, the Scan Cycle Time is
determined by the time between RPG transitions ( RPG NPN output
changes from OFF to ON). If the time between transitions is less
than the Trigger Delay Time, scan data will be lost.
Scan Cycle
Trigger Delay Time
See
Note 1
Data Ready
Outputs Stable
(Limits NPN output ON when
limits exceed setpoint)
B & S
Auto Restart
Jumpers
2
4
22us
22us
Yes
22us
Yes
22us
Yes
Yes
22us
22us
Yes
22us
Yes
22us
Yes
Yes
12us
Yes
Yes
8
Yes
Yes
Yes
Yes
Yes
3