Roubleshooting (C Ontinued ); R Eplacement (M Onthly ) - Kaivac 1250 Operator's & Parts Manual

Ntc (no-touch cleaning)
Hide thumbs Also See for 1250:
Table of Contents

Advertisement

4.3 t
RouBleshooting
cautIon:
always unplug machine before lifting electric cover assembly.
arEa
ProBlEm
Not enough chemical
Chemical line blows off
Chemical Injection
safety cap
System continued
Water back flows into
chemical bottle
Dump hose will not empty
tank
Dump System
Dump hose leaks
Wheels will not roll;
Wheels and Casters
rubbing
Floor streaks
Squeegee head does not
easily rotate when
installed on wand
Squeegee Head
Head will not stay on wand
Premature blade wear
Sucks to the floor too
tightly
P a g e |
1 4
4.0 Troubleshooting and Upkeep
PossIBlE causE
solutIon
Metering tip plugged
Remove and clean
Wrong metering tip
Check and replace per chart
Debris in injector
Remove safety cap from
chemical and blow small
amounts of compressed air
into line
Bad seat on injector check
Check injector o-ring or
valve
replace
Bad safety cap
Replace safety cap
Dump hose cap not
Remove cap
removed
Clog in bottom of tank
Tip dump contents, remove
debris
Hose cut
If leak is less than 4" from
tank side, cut and reattach,
or replace
Clamp loose
Tighten hose clamp
Dump cap missing
Replace cap
Flat tires
Inflate tires to 30 p.s.i.
Debris wrapped around
Check for debris on axle
axle
Bearings tight
Grease bearings
Wheels too loose on axle
Remove wheel, add
washers to take up slack
Bearings falling out
Replace bearing assembly
Worn blades or wheels
Replace wheels and/or blades
Brass ring on wand not in
Loosen coupling nut and
groove
re-position head on groove
Coupling nut too tight
Loosen 1/2 turn
Coupling nut cracked
Replace
Brass ring worn
Replace
Squeegee wheels worn
Check wheels for wear/
replace
Squeegee wheels worn
Check wheels for wear/
replace
Customer/Technical Support
|
1-800-287-1136
4.4 t
t
RouBleshooting
iPs
• poor Vacuum pickup
1. Check Squeegee Blades. If blades are worn or damaged, replace Squeegee head.
2. Clean float cage.
3. Check for leaks in the Vacuum hose or Gasket.
4. Check for clogged Vacuum hose.
5. Check to see if float ball was tripped.
• Vacuum shuts off prematurely
1. Check Float Cage; clean if dirty.
2. Cleaning Chemicals may be producing too much foam. Use correct Chemicals.
• other issues? contact technical support
phone:
United States and Canada: 1-800-287-1136
International: 1-513-887-4600
email:
info@kaivac.com
For Technical Support Contact Form go to:
https://www.kaivac.com/contactus.php
and choose Technical Support tab.
4.5 R
(m
ePlacement
onthly
The following tasks should be performed monthly to keep your system operating at peak performance.
rEPlacE If Worn
Check for worn squeegee blades.
Worn blades cause streaking and
loss of vacuum suction.
©2018 Kaivac, Inc. All Rights Reserved
|
www.kaivac.com
4.0 Troubleshooting and Upkeep
)
Unscrew cuff at end
of Vac Wand, remove
old head and replace
with new every 6-8
weeks for optimal
performance.
P a g e |
1 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

17502150

Table of Contents