4.1 t

RouBleshooting

cautIon:
always unplug machine before lifting electric cover assembly.
arEa
ProBlEm
No Power to pump or
vac motor
Electrical
Electrical burning smell
No/Weak vacuum
Vacuum System
Moisture from exhaust
No air flow
Moisture from exhaust
Blow Dry System
Suction, not blow action
P a g e |
1 2

4.0 Troubleshooting and Upkeep

PossIBlE causE
solutIon
Machine not plugged in
Plug machine in
Switch not "on"
Check switches for "on"
GFCI tripped
Test and reset GFCI
Building circuit overloaded
Check and reset circuit
Switch wires loose
Disconnect power and check for
loose wire
Connections loose
Disconnect power and check for
loose wire under panel
Vac motor brushes worn
Remove vac motor and repair
Vac motor hung up
Release pressure on hose and jog
vac switch, or replace
Pump motor hung up
Release pressure on hose and jog
pump switch, or replace
Vac tank full
Empty vac tank
Squeegee blades or wheels
Replace wheels or blades and check
worn
periodically
Float shutoff screen dirty
Spray off float screen to clean
Float ball stuck
Tap float and release/clean
Damaged hose
Cut and repair/replace
Dump hose plug missing
Contact dealer and replace
Access lid not right
Tighten lid hand tight
Vacuum hose plugged
Flush hose to remove debris
Too much liquid in vac hose
Allow air in when vacuuming
Vac hose still wrapped
Unwrap vac hose fully
Exhaust plugged
Remove HEPA filter and clean
Leak in vac tank
If repairable, clean and dry affected
area and seal with silicone
HEPA filter clogged
Remove HEPA filter and clean
Vac tank full
Dump vac tank
Float shutoff missing
Replace
Excessive foam in vac tank
Use defoamer
Hose disconnected
Reconnect hose
Water in blow hose
Dry blow line
Vacuum hose connected to
Reconnect to vac motor exhaust
vac tank
hose
Customer/Technical Support
|
4.2 t
RouBleshooting
cautIon:
arEa
High Pressure
System
Chemical
Injection System
1-800-287-1136
©2018 Kaivac, Inc. All Rights Reserved
always unplug machine before lifting electric cover assembly.
ProBlEm
PossIBlE causE
Out of water
Gun nozzle plugged
Air in pump (vapor lock)
Gun orifice missing
Water tank filter plugged
In-line bowl filter plugged
Bowl filter lid loose
No water from
Pressure hose damaged
pump or low
Quick disconnect leaking
pressure
Injector plugged
Pulse hose damaged
Regulator failed
Hose kinked
Seals in pump need
replaced
Bad fan pattern
Debris in nozzle
or pinpoint
pattern on gun
Orifice damaged
Out of chemical
Safety cap not secure
Chemical valve "off"
Safety cap plugged
Spray gun in wrong mode
Metering tip plugged
No chemical
Injector plugged
flow
Air entering system
Injector installed
backwards
Kink in chemical line
|
www.kaivac.com
4.0 Troubleshooting and Upkeep
solutIon
Fill water tank
Remove orifice with Allen wrench and clean
Use power prime technique
Replace orifice
Clean tank and filter
Remove filter cover and clean
Gently tighten bowl cover
Repair or replace
Tighten or replace
Remove safety cap from chemical and blow
small amounts of compressed air into line
Repair or replace
Replace
Unkink and check for damage
Remove and replace seals
Remove orifice with Allen wrench and clean
Remove and replace
Refill chemical
Check safety cap/tighten
Check on/off valve
Replace cap
Make sure gun nozzle is pulled out away
from gun chemical mode
Check metering tip for clog
Remove safety cap from chemical and blow
small amounts of compressed air into line
Check for air entering system around
chemical lines or injector
If fluttering or pulsing sound can be heard
while spraying or when machine is running,
it is possible that your injector is in
backwards. Remove; reinstall.