Download Print this page

Panasonic SL-VVMES2 Instruction Manual page 8

Sensor and wire-saving link system s-link

Advertisement

5. Assignment on Program
VME bus
address
(byte unit)
+0000H
to
S-LINK V I/O data
+003FH
+0040H
Transmission mode /
I/O control point
+0042H
to
I/O setting
+0045H
+0046H
S-LINK V I/O unit
connected node number
+0048H
Not usable (= 04)
+004AH
Error No. / Error state
+004CH
Command execution request
register
+004EH
Command completion re-
sponse register
+0050H
Bank change-over request
register
+0052H
Bank change-over response
register
+0054H
Communication stop / Reset R/W
+0056H
Input hold
Input change interruption
Input change interruption oc-
currence condition
Error interruption
+0058H
to
Not usable (= 00) (unable to write into it)
+007FH
+0080H
Address information bank
to
register
+00BFH
+00C0H
Input interrupting
to
allowing address
+00FFH
1RWHV  +/ LV WKH ¿UVW DGGUHVV LQ ,2 UHJLRQ DVVLJQHG E\ ,2 ¿UVW DGGUHVV VHWWLQJ VZLWFK
2) For "HL00 + 0080 to HL00 + 00BF or HL00 + 0180 to HL00 + 01BF," the contents of the assignment vary
depending on the contents of the bank change-over request register and the bank change-over response
register.
3) Reading out / Writing in "HL00 + 0080 to HL00 + 00BF or HL00 + 0180 to HL00 + 01BF" must be done after
the contents of the bank change-over request register and those of the bank change-over response register
match.
7
SL-VVMES2 memory map
Port 1
64 bytes
R/W
(32 words)
2 bytes
R
(1 word)
4 bytes
R/W
(2 words)
2 bytes
R
(1 word)
2 bytes
(1 word)
2 bytes
R
(1 word)
2 bytes
R/W
(1 word)
2 bytes
R
(1 word)
2 bytes
R/W
(1 word)
2 bytes
R
(1 word)
2 bytes
(1 word)
2 bytes
R/W
(1 word)
64 bytes
R
(32 words)
64 bytes
R/W
(32 words)
VME bus
address
(byte unit)
+0100H
to
S-LINK V I/O data
+013FH
+0140H
Transmission mode /
I/O control point
+0142H
to
I/O setting
+0145H
+0146H
S-LINK V I/O unit
connected node number
+0148H
Not usable (= 04)
+014AH
Error No. / Error state
+014CH
Command execution request
register
+014EH
Command completion re-
sponse register
+0150H
Bank change-over request
register
+0152H
Bank change-over response
register
+0154H
Communication stop / Reset R/W
+0156H
Input hold
Input change interruption
Input change interruption oc-
currence condition
Error interruption
+0158H
to
Not usable (= 00) (unable to write into it)
+017FH
+0180H
Address information bank
to
register
+01BFH
+01C0H
Input interrupting
to
allowing address
+01FFH
R/W: Read out / Write in, R: Read out only
Port 2
64 bytes
R/W
(32 words)
2 bytes
R
(1 word)
4 bytes
R/W
(2 words)
2 bytes
R
(1 word)
2 bytes
(1 word)
2 bytes
R
(1 word)
2 bytes
R/W
(1 word)
2 bytes
R
(1 word)
2 bytes
R/W
(1 word)
2 bytes
R
(1 word)
2 bytes
(1 word)
2 bytes
R/W
(1 word)
64 bytes
R
(32 words)
64 bytes
R/W
(32 words)

Advertisement